Характеристики

Output signal switching signal; analog signal; IO-Link
Measuring range -401...401
Medium temperature -25...150
Electrical design PNP/NPN
Process connection G 1 external thread sealing cone

Все характеристики

Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-1000...1000 mbar-14.5...14.5 psi-401...401 inH2O-100...100 kPa
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature -25...150
Min. bursting pressure
30000 mbar435 psi3000 kPa
Pressure rating
10000 mbar145 psi1000 kPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications according to CRN) 10
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
Step response time analog output 30
Min. response time of switching output (dAP) 3
Step response time analog output 7
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring range
-1000...1000 mbar-14.5...14.5 psi-401...401 inH2O-100...100 kPa
Set point SP
-997...1000 mbar-14.46...14.5 psi-400...401 inH2O-4.9...100 kPa
Reset point rP
-1000...997 mbar-14.5...14.46 psi-401...400 inH2O-100...99.7 kPa
Analog start point
-1000...599 mbar-14.5...8.68 psi-401...240 inH2O-100...59.9 kPa
Analog end point
-599...1000 mbar-8.68...14.5 psi-240...401 inH2O-59.9...100 kPa
Min. difference between SP and rP
3 mbar0.05 psi2 inH2O0.3 kPa
In steps of
1 mbar0.01 psi1 inH2O0.1 kPa
Factory setting
SP1 =-500 mbarrP1 = -540 mbar
SP2 = 500 mbarrP2 = 460 mbar
ASP = -1000 mbarAEP = 1000 mbar
dAP = 2.00 sdAA =2.00 s
Accuracy ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability ± 0,2
Resolution 0.2
Switch point accuracy < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation < ± 0,15; (Turn down 1:1)
Hysteresis deviation < ± 0,15; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range
Temperature rangetotal deviation
-25...15 °CCharacteristics deviation ± 0,05 % of the span / 10 K
15...80 °CCharacteristics deviation
80...150 °CCharacteristics deviation ± 0,1 % of the span / 10 K
Notes on the accuracy / deviation for further details see section Diagrams and graphs
Damping process value dAP 0...99.99
Damping for the analog output dAA 0...99.99
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, high resolution
SIO mode yes
Required master port class A
Min. process cycle time 5.6
IO-Link resolution pressure 0.1
IO-Link resolution temperature 0.2
IO-Link process data (cyclical)
Functionbit length
pressure32
temperature32
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs
Type of operationDeviceID
default1151
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 214
Note on approval
Factory certificate available as download at www.factory-certificate.ifm
UL approval
UL approval numberJ049
File number ULE174189
Weight 384.6
Housing tubular
Dimensions Ø 50 / L = 106
Material stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE
Min. pressure cycles 100 million
Tightening torque 20
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Display
Display unitLED, green
Switching statusLED, yellow
Function displayalphanumeric display, 4-digit
Measured valuesalphanumeric display, 4-digit
Display unit mbar; psi; kPa; inH2O
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Robust stainless steel design for the requirements of the food and beverage industry
Hygienic, flush design
Resistant to high-pressure cleaning with aggressive cleaning agents
High temperature resistance and high protection rating
Programmable analog and switching output
Integrated temperature measurement via IO-Link
Convenient operation via buttons or parameter setting via IO-Link