Характеристики

Output signal switching signal; analog signal; IO-Link
Measuring range -5...100.4
Medium temperature -25...150
Electrical design PNP/NPN
Process connection G 1 external thread sealing cone

Все характеристики

Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-12.4...250 mbar-5...100.4 inH2O-1.24...25 kPa-126...2550 mmWS
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature -25...150
Min. bursting pressure
30000 mbar12044 inH2O3000 kPa
Pressure rating
6000 mbar2400 inH2O600 kPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications according to CRN) 6
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
Step response time analog output 30
Min. response time of switching output (dAP) 3
Step response time analog output 7
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring range
-12.4...250 mbar-5...100.4 inH2O-1.24...25 kPa-126...2550 mmWS
Set point SP
-12...250 mbar-4.8...100.4 inH2O-1.2...25 kPa-122...2549 mmWS
Reset point rP
-12.4...249.6 mbar-5...100.2 inH2O-1.24...24.96 kPa-126...2545 mmWS
Analog start point
-12.4...199.4 mbar-5...80.1 inH2O-1.24...19.94 kPa-126...2033 mmWS
Analog end point
38.2...250 mbar15.3...100.4 inH2O3.82...25 kPa390...2549 mmWS
Min. difference between SP and rP
0.5 mbar0.2 inH2O0.05 kPa5 mmWS
In steps of
0.1 mbar0.1 inH2O0.01 kPa1 mmWS
Factory setting
SP1 =62.5 mbarrP1 = 57.5 mbar
SP2 = 187.5 mbarrP2 = 182.5 mbar
ASP = 0.00 mbarAEP = 250 mbar
dAP = 2.00 sdAA =2.00 s
Accuracy ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability ± 0,2
Resolution 0.2
Switch point accuracy < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation < ± 0,15; (Turn down 1:1)
Hysteresis deviation < ± 0,15; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range
Temperature rangetotal deviation
-25...15 °CCharacteristics deviation ± 0,1 % of the span / 10 K
15...80 °CCharacteristics deviation
80...150 °CCharacteristics deviation ± 0,15 % of the span / 10 K
Notes on the accuracy / deviation for further details see section Diagrams and graphs
Damping process value dAP 0...99.99
Damping for the analog output dAA 0...99.99
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, high resolution
SIO mode yes
Required master port class A
Min. process cycle time 5.6
IO-Link resolution pressure 0.01
IO-Link resolution temperature 0.2
IO-Link process data (cyclical)
Functionbit length
pressure32
temperature32
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs
Type of operationDeviceID
default1152
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 214
Note on approval
Factory certificate available as download at www.factory-certificate.ifm
UL approval
UL approval numberJ049
File number ULE174189
Weight 382.9
Housing tubular
Dimensions Ø 50 / L = 106
Material stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE
Min. pressure cycles 100 million
Tightening torque 20
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Display
Display unitLED, green
Switching statusLED, yellow
Function displayalphanumeric display, 4-digit
Measured valuesalphanumeric display, 4-digit
Display unit mbar; kPa; inH2O; mmWS
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Robust stainless steel design for the requirements of the food and beverage industry
Hygienic, flush design
Resistant to high-pressure cleaning with aggressive cleaning agents
High temperature resistance and high protection rating
Programmable analog and switching output
Integrated temperature measurement via IO-Link
Convenient operation via buttons or parameter setting via IO-Link