| Output function |
normally open |
| Sensing range |
10 |
| Housing |
Threaded type |
| Dimensions |
M30 x 1.5 / L = 80 |
| Application |
simple evaluation of rotating and linear movement with regard to underspeed; blocking |
| Nominal voltage AC |
20...250 |
| Nominal voltage DC |
20...250 |
| Nominal frequency AC |
45...65 |
| Protection class |
II |
| Reverse polarity protection |
yes |
| Total number of outputs |
1 |
| Output function |
normally open |
| Max. voltage drop switching output DC |
7.5 |
| Minimum load current |
6 |
| Max. leakage current |
1.5 |
| Permanent current rating of switching output AC |
200 |
| Permanent current rating of switching output DC |
100 |
| Short-time current rating of switching output |
2200; (20 ms / 0,5 Hz) |
| Short-circuit proof |
no |
| Overload protection |
no |
| Sensing range |
10 |
| Sensing range adjustable |
no |
| Real sensing range Sr |
10 ± 10 % |
| Operating distance |
0...8.1 |
| Setting range |
5...3600 |
| Measuring principle |
inductive |
| Correction factor |
steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminum: 0.5 / copper: 0.4 |
| Hysteresis |
10 |
| Start-up delay |
12 |
| Max. damping frequency |
4800 |
| Adjustment of the switch point |
multiturn potentiometer |
| Ambient temperature |
-20...60 |
| Storage temperature |
-25...60 |
| Protection |
IP 65; IP 67 |
| Approval |
IECEx BVS 17.0094X |
| ATEX marking |
II 3D Ex tc IIIC T80°C Dc X |
| EMC |
|
| MTTF |
435 |
| Weight |
314 |
| Housing |
Threaded type |
| Mounting |
flush mountable |
| Dimensions |
M30 x 1.5 / L = 80 |
| Thread designation |
M30 x 1.5 |
| Material |
brass special coating; PA; TPE-U |
| Display |
| Switching status | 2 x LED, yellow |
|
| Connection |
Cable: 2 m, PUR; 2 x 0.5 mm² |
| Items supplied |
|
| Remarks |
| Recommendation Check the safe functioning of the unit after a short circuit. |
|
| Pack quantity |
1 pcs. |