Output signal switching signal; IO-Link; (configurable)
Measuring range 0...250
Medium temperature -40...90
Electrical design PNP/NPN
Process connection G 1/4 external thread

Все характеристики

Number of inputs and outputs Number of digital outputs: 2
Measuring range
0...250 bar0...3626 psi0...25 MPa
Process connection threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5
Measuring element metallic thin film cell
Application for industrial applications
Media liquids and gases
Medium temperature -40...90
Min. bursting pressure
1200 bar17400 psi120 MPa
Pressure rating
625 bar9060 psi62.5 MPa
Note on pressure rating
static
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressure relative pressure
Operating voltage 18...30 DC
Current consumption < 15
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time < 0.3
Number of inputs and outputs Number of digital outputs: 2
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 100
Switching frequency DC < 170
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring range
0...250 bar0...3626 psi0...25 MPa
Set point SP
2.5...250 bar37...3626 psi0.25...25 MPa
Reset point rP
1.3...248.8 bar18...3608 psi0.13...24.88 MPa
In steps of
0.1 bar1 psi0.01 MPa
Factory setting
SP1 = 62.5 barrP1 = 57.5 barou1 = Hno;
SP2 = 187.5 barrP2 = 182.5 barou2 = Hno;
dS1/dS2 = 0 msdr1/dr2 = 0 ms
coF = 0 %P-n = PnPdAP= 60 ms
Switch point accuracy < ± 0,5 (nach DIN EN 61298-2)
Repeatability < ± 0,05; (with temperature fluctuations < 10 K)
Characteristics deviation < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity deviation < ± 0,1 (BFSL) / < ± 0,2 (LS)
Hysteresis deviation < ± 0,2
Long-term stability < ± 0,1; (per 6 months)
Temperature coefficient zero point < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Temperature coefficient span < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Response time < 3
Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 5
Supported DeviceIDs
Type of operationDeviceID
default709
Ambient temperature -40...90
Storage temperature -40...100
Protection IP 67; IP 69K
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27500 g (1 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 667.77
UL approval
UL approval numberJ016
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 64.5
Housing tubular
Dimensions Ø 19 / L = 66
Material stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PEI
Materials (wetted parts) stainless steel (1.4305 / 303); stainless steel (630/1.4542/17-4 PH)
Min. pressure cycles 60 million; (at 1.2 times nominal pressure)
Tightening torque 25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating)
Process connection threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5
Process connection sealing FKM (DIN EN ISO 1179-2)
Restrictor element integrated yes
Remarks
BFSL = Best Fit Straight Line
LS = limit value setting
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A

Приемущества

Compact housing for use where space is restricted
Very high overpressure and vacuum resistance
Robust stainless steel housing with high shock and vibration resistance
Lifespan of more than 60 million pressure cycles
Two programmable switching outputs, one of them with IO-Link communication interface
User-friendly communication and parameterization via IO-Link