Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

SV5614 – фото
Фото
Видео

На SV5614

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output function analog
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Measuring range 32...634
Measuring range temperature 14...194 °F
Process connection 1/2" NPT Internal thread DN10

Все характеристики

Number of inputs and outputs Number of analog outputs: 2
Measuring range
32...634 gph0.55...10.55 gpm
Process connection threaded connection 1/2" NPT Internal thread DN10
System gold-plated contacts
Application for industrial applications
Media water; glycol solutions; Coolants
Medium temperature 14...194
Pressure rating
12 bar174 psi1.2 MPa
Note on pressure rating
up to 40 °C
MAWP (for applications according to CRN) 4.8
Operating voltage 18...30 DC
Current consumption < 30
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time < 3
Measuring principle Vortex
Number of inputs and outputs Number of analog outputs: 2
Total number of outputs 2
Output signal analog signal
Number of analog outputs 2
Analog current output 4...20
Max. load 500
Short-circuit protection yes
Overload protection yes
Measuring range
32...634 gph0.55...10.55 gpm
Display range
0...760 gph0...12.7 gpm
Resolution
2 gph0.05 gpm
Analog start point ASP
0...508 gph0...8.45 gpm
Analog end point AEP
126...634 gph2.1...10.55 gpm
In steps of
2 gph0.05 gpm
Measuring dynamics 1:20
Dynamic response T05 / T09 T09 = 6
Response time 1; (dAP = 0)
Damping process value dAP 0...5
Parameter setting options Damping for the analog output dAA; Display unit
Ambient temperature 32...140
Note on ambient temperature
medium temperature < 176 °F
medium temperature < 194 °F: 32...122 °F
Storage temperature -4...176
Protection IP 65; IP 67
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-275 g (11 ms)
Vibration resistance
DIN EN 60068-2-6with water / 10...50 Hz 1 mm
with water / 50...2000 Hz 2 g
MTTF 342
UL approval
UL approval numberI002
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 466
Housing rectangular
Dimensions 119 x 45 x 72
Material stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque 30
Process connection threaded connection 1/2" NPT Internal thread DN10
Display
Color display 1,44", 128 x 128 pixels
2 x LED, yellow
Remarks
MW = Measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Reliable detection of flow and medium temperature
Precise linearized analog output
Display can be rotated for optimum alignment
Clearly readable color display with red/green color change
Suitable for water, deionized water and cooling water