MS-3 35-343001-18 Release Notes

*******************************

-18

-From -17 to -18.
-Added UPC Supplemental Type to menu. Options are: Supplemental Type: 0 = Both (default); 1 = 2 Characters Only; 2 = 5 Characters Only.
-Changed 4 defaults to match ESP:
<K409,,,300> Long life warning is now 300.
<K780,1> Relay # 1 Trend Analysis Mode = No Read.
<K781,1> Relay # 2 Trend Analysis Mode = No Read.
<K782,1> Relay # 3 Trend Analysis Mode = No Read.

-17

-From -16 to -17.
-Fixed an RTS/CTS issue.

-16

-From -15 to -16.
-Added two new factory settings.

-15

-From -14 to -15.
-Incorporated "Fixed Map" Scan Width Enhance table.

-14

-From -13 to -14.
-Fixed the problem of having a 2-second wait after <H> command where external triggering was being ignored.
-Fixed laser so it no longer blinks on and off once per second. The blink was visible in the left corner of the window with Laser On/Off enabled and the scanner idle.

-13

-From -12 to -13.
-Fixed the problem of not always executing serial trigger when it is received in the same string as <H> command. Example: <H><&> where '&' is the serial trigger character.
-Fixed the problem of not being able to decode Full ASCII Code 39, since symbol grading was added in -11.
-Fixed the Aux Port to check if Multisymbol Separator has been disabled before using it.
-Fixed the problem of reverting to NOVRAM settings for Gain, Scan Speed, and Laser Power, with the <A> command or any other type of reset. This was introduced in -12 when fixing <Zrc>.
-Fixed bug with <KD> command.
-Fixed <K411> so Laser High and Laser Low enable/disable functions correctly.
-Fixed Code 128 bug.
-Fixed potential Daisy Chain Autoconfigure bug.

-12

-From -11 to -12.
-Fixed <Arc> <Zc> gain, motor, and laser power issue.
-Fixed occasional <K200>-related scanner freeze issue.

-11

-From -10 to -11.
-Fixed bug relating to initialization of outputs.
-Fixed reads per trigger mode not to output more symbol data than what is enabled using <K222> or <KL>.
-Included "NO SYMBOL" message in menu.
-Added Range Mode to Interleaved 2 of 5.
-Fixed Pharmacode using all narrow or all wide option.
-Fixed aggressive read mode for Code 93, Codabar, and Interleaved 2 of 5.
-Fixed use of serial level mode in Daisy Chain.
-Fixed undelimited serial start trigger to prevent triggering in level mode if no end character is defined. (Prevents the unit from getting stuck in Read Cycle.)
-Added command to enable ESP support.
-Fixed UPC Supplementals bug.
-Modified command processing not to require leading zeros.
-Added support for digital O-scope feature in ESP.
-Added support for Microscan grading.
-Added support for decode direction output.
-Fixed text output in menus for symbol types.
-Added Latch Mode functionality to outputs. Followed MS-9 methodology with new master doubling as input for Latch Mode. Also added option for EZ button unlatch.
-Fixed problem with NW7 check digit in Codabar that didn't work for value of 0.
-Fixed problem entering Read Rate with EZ button in Continuous Read 1 mode.
-Changed undelimited serial start and stop to allow them to be used as delimited triggers for serial level mode in multidrop.
-Added functionality to EZ button allowing it to be used to default on power-on and save settings at power-on.
-Fixed auto laser frame to work with laser on/off enabled.
-Fixed communication setup in autocalibration routine to prevent commands entered during fixed parameter autocal to cause command processing problems after autocal completes.
-Fixed master symbol command to check for ")" before processing data.
-Fixed ESP mode to function in multidrop.
-Fixed serial verification bug.
-Fixed multidrop bug.
-Added ability to change laser power in ESP.
-Fixed trend analysis bug.
-Fixed master label database command bug.
-Fixed bug when exiting autocalibration to properly map AGC mode for saving.
-Fixed user-defined so it doesn't turn on 422 transmitter unless host mode is set to 422. Prevents 422 and 232 line contention.

-10

-Released MS-3 App Code.