Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

VVB302 – фото
VVB302 – фото
VVB302 – фото
Фото
Видео

На VVB302

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Frequency range 2...5600
Protection IP 67, IP 68, IP 69
Approval CE, UKCA, cULus
Output function normally open / closed; (configurable)

Все характеристики

Frequency range 2...5600
Measuring principle capacitive
Design DataScience condition monitoring
Application industrial machines
Operating voltage 18...30 DC
Current consumption < 50
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Type of sensor Microelectromechanical system (MEMS)
Number of inputs and outputs Number of digital outputs: 2
Output signal switching signal; IO-Link
Electrical design PNP/NPN; (configurable)
Number of digital outputs 2
Output function normally open / closed
Max. voltage drop switching output DC 2
Max. current load per output 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Note on setpoint SP
configurable
Frequency range 2...5600
Measuring principle capacitive
Number of measurement axes 3
Measuring range of vibration 0...0.3
Resolution 0.0001
Set point SP 0.0002...0.3
Reset point rP 0...0.2998
Measuring range of vibration 0...156.91
Resolution 0.01
Set point SP 2...156.91
Reset point rP 0...154.91
Measuring range -30...80
Resolution 0.1
Set point SP -28...80
Reset point rP -30...78
Accuracy ± 5
Linearity deviation 2; (% of the final value)
Accuracy 2-4000Hz +/- 10%, 4000..5600Hz -3dB
Accuracy 2-5000Hz +/- 10%, 5000...5600Hz -3dB
Accuracy 2-5000Hz +/- 10%, 5000...5600Hz -3dB
Parameter setting options IO-Link
Diagnostic functions self-test
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9: 2013-07
Profiles
BLOBBinary Large Object transfer
Common - I&DIdentification and Diagnosis
FunctionLocator
FunctionProductURI
SIO mode yes
Required master port class A
Min. process cycle time 4.1
IO-Link process data (cyclical)
Functionbit length
v-RMS (x)16
v-RMS (y)16
v-RMS (z)16
v-RMS (Magnitude)16
scaling / v-RMS8
a-Peak (x)16
a-Peak (y)16
a-Peak (z)16
a-Peak ( Magnitude)16
a-RMS (x)16
a-RMS (y)16
a-RMS (z)16
a-RMS ( Magnitude)16
scaling / a-Peak/a-RMS8
temperature16
scaling / temperature8
device status4
unbalance / bearing event1
virtual switching output (v-ou1)1
binary switching information2
IO-Link functions (acyclical) filter for v-RMS, a-RMS, a-Peak; Hysteresis; window; Switch points; switching logic; unbalance measurement; machine operating hours counter; bearing analysis (BearingScout)
Supported DeviceIDs
Type of operationDeviceID
default1778
Note
For further information please see the IODD PDF file at "Downloads"
Ambient temperature -30...80
Storage temperature -30...80
Protection IP 67; IP 68; IP 69
EMC
EN IEC 61000-6-2noise immunity / industrial environments
EN IEC 61000-6-3noise emission in domestic areas
Shock resistance
DIN EN 60068-2-2750 g 11 ms
500 g 1 ms
Vibration resistance
DIN EN 60068-2-620 g / 10...3000 Hz
MTTF 480
UL approval
UL approval numberL006
File number ULE251902
Standard mechanical vibration; ISO 10816-3; ISO 2954; ISO 20816-3
Weight 98.4
Type of mounting mounting screw
Material housing: stainless steel (1.4404 / 316L)
Tightening torque 4.6
Display
Power1 LED, green
fault1 LED, red
Items supplied
mounting screw: 1 x (M5 x 25 mm)
Pack quantity 1 pcs.
Connector: 1 x M12; coding: A; Maximum cable length: 20 m

Приемущества

reliable and permanent monitoring of condition parameters in 3 axes
condition-based analysis of imbalance and rolling element bearing damages
suited for harsh industrial environments, with sensor self-test and status LED
asynchronous transmission of raw data (BLOB) and integrated characteristic value history
User-friendly communication and parameterization via IO-Link