Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

VVB301 – фото
VVB301 – фото
VVB301 – фото
Фото
Видео

На VVB301

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Frequency range 2...5600
Protection IP 67, IP 68, IP 69
Approval CE, UKCA, cULus
Output function normally open / closed; (configurable)

Все характеристики

Product characteristics
Frequency range 2...5600
Measuring principle capacitive
Application
Design Basic condition monitoring
Application industrial machines
Electrical data
Operating voltage 18...30 DC
Current consumption < 50
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Type of sensor Microelectromechanical system (MEMS)
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Output signal switching signal; IO-Link
Electrical design PNP/NPN; (configurable)
Number of digital outputs 2
Output function normally open / closed
Max. voltage drop switching output DC 2
Max. current load per output 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Note on setpoint SP <table><tr><td> configurable</td></tr></table>
Frequency range 2...5600
Measuring principle capacitive
Number of measurement axes 3
v-RMS (x-y-z)
Measuring range of vibration 0...0.3
Resolution 0.0001
Set point SP 0.0002...0.3
Reset point rP 0...0.2998
a-Peak / a-RMS (x-y-z)
Measuring range of vibration 0...156.91
Resolution 0.01
Set point SP 2...156.91
Reset point rP 0...154.91
Crest (x-y-z)
Measuring range of vibration 1...50
Resolution 0.1
Set point SP 2...50
Reset point rP 1...49
Temperature measurement
Measuring range -30...80
Resolution 0.1
Set point SP -28...80
Reset point rP -30...78
Accuracy / deviations
Accuracy ± 5
Linearity deviation 2; (% of the final value)
X axis
Accuracy 2-4000Hz +/- 10%, 4000..5600Hz -3dB
Y axis
Accuracy 2-5000Hz +/- 10%, 5000...5600Hz -3dB
z-axis
Accuracy 2-5000Hz +/- 10%, 5000...5600Hz -3dB
Software / programming
Parameter setting options IO-Link
Diagnostic functions self-test
Interfaces
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9: 2013-07
Profiles <table><tr><td>BLOB</td><td>Binary Large Object transfer</td></tr><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Locator</td></tr><tr><td>Function</td><td>ProductURI</td></tr></table>
SIO mode yes
Required master port class A
Min. process cycle time 3.3
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>v-RMS (x-y-z)</td><td>16</td></tr><tr><td>velocity scaling</td><td>8</td></tr><tr><td>velocity measurement axis</td><td>4</td></tr><tr><td>a-Peak (x-y-z)</td><td>16</td></tr><tr><td>a-RMS (x-y-z)
IO-Link functions (acyclical) filter for vibration velocity (v); filter for vibration acceleration (a); Hysteresis; window; Switch points; switching logic; unbalance measurement; machine operating hours counter
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1703</td></tr></table>
Note <table><tr><td> For further information please see the IODD PDF file at "Downloads"</td></tr></table>
Operating conditions
Ambient temperature -30...80
Storage temperature -30...80
Protection IP 67; IP 68; IP 69
Tests / approvals
EMC <table><tr><td>EN IEC 61000-6-2</td><td>noise immunity / industrial environments</td></tr><tr><td>EN IEC 61000-6-3</td><td>noise emission in domestic areas</td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>50 g 11 ms</td></tr><tr><td></td><td>500 g 1 ms</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>20 g / 10...3000 Hz</td></tr></table>
MTTF 480
UL approval <table><tr><td>UL approval number</td><td>L006 </td></tr><tr><td>File number UL</td><td>E251902 </td></tr></table>
Standard mechanical vibration; ISO 10816-3; ISO 2954; ISO 20816-3
Mechanical data
Weight 98.2
Type of mounting mounting screw
Material housing: stainless steel (1.4404 / 316L)
Tightening torque 4.6
Displays / operating elements
Display <table><tr><td>Power</td><td>1 LED, green</td></tr><tr><td>fault</td><td>1 LED, red</td></tr></table>
Accessories
Items supplied <table><tr><td>mounting screw: 1 x (M5 x 25 mm)</td></tr></table>
Remarks
Pack quantity 1 pcs.
Electrical connection

Приемущества

reliable and permanent monitoring of condition parameters in 3 axes
condition-based analysis of imbalance and rolling element bearing damages
suited for harsh industrial environments, with sensor self-test and status LED
asynchronous transmission of raw data (BLOB) and integrated characteristic value history
User-friendly communication and parameterization via IO-Link