| Measuring range |
|
| Process connection |
bolt-on sensor DN50 ( Ø 48...54 mm) |
| System |
gold-plated contacts |
| Measuring element |
1 x Pt 1000; (to DIN EN 60751, class A) |
| Installation |
Contact sensor for solid bodies; clamp-on solution |
| Protection class |
III |
| Measuring range |
|
| Accuracy |
± (0,15 K + 0,002 x|T|); (ambient temperature influence on the accuracy: 0,02 x (Ta - T)) |
| Dynamic response T05 / T09 |
7,5 / 25; (reference values for moving water : (> 0,4 m/s)) |
| Ambient temperature |
-25...80 |
| Protection |
IP 69K |
| MTTF |
22831 |
| Weight |
168.2 |
| Design |
Surface temperature probe |
| Dimensions |
102 x 81 x 45 |
| Material |
Mounting clamp: stainless steel (1.4404 / 316L); housing: PPSU; Gasket: FKM |
| Process connection |
bolt-on sensor DN50 ( Ø 48...54 mm) |
| Remarks |
| Ta = Ambient temperature | | T = Process temperature |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |