| Communication interface |
CAN |
| Housing |
rectangular |
| Dimensions |
80 x 80 x 45 |
| Radio approval for |
EU/RED; USA; Canada; Great Britain; Australia; Chile; Mexico; Namibia; New Zealand; South Africa |
| Note on radio approval |
| The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”. |
|
| Operating voltage |
9...32 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4) |
| Current consumption |
< 300; (mean value: 150 mA) |
| Power consumption |
9; (maximum) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Max. power-on delay time |
1000 |
| Operating frequency [GHz] |
|
| Maximum radiated average power spectral density EIRP [dBm/MHz] |
|
| Radiated peak power EIRP [dBm] |
|
| Range |
0.1...50; (based on E23014) |
| Angle of aperture cylindrical |
|
| Note |
static objects in the range < 1 m are not stably detected in area mode |
| Measuring range |
0.1...50; (see diagram:) |
| Sampling rate |
20 |
| Parameter setting options |
via PC with ifm Vision Assistant |
| Communication interface |
CAN |
| Number of CAN interfaces |
1 |
| Transmission rate |
250 (125...1000) kBaud |
| Protocol |
SAE J1939 |
| Factory settings |
| Baud rate: 250 | | device address (ECU): 126 | | UDS interface: 1000 kBaud |
|
| Usage type |
Parameter setting; Data transmission |
| Note |
| For further information please refer to the software manual available under "Downloads" |
|
| Ambient temperature |
-40...85 |
| Storage temperature |
-40...85 |
| Protection |
IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps) |
| EMC |
| DIN EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | DIN EN 61000-4-3 HF radiated | 10 V/m | | DIN EN 61000-4-4 Burst | 2 kV | | DIN EN 61000-4-6 HF conducted | 10 V | | DIN EN 61000-6-2 | noise immunity / industrial environments | | EN 55032 emission | class A |
|
| Impact resistance |
|
| Vibration resistance |
| DIN EN 60068-2-6 Fc | 10 g 10 frequency cycles, 1 octave/minute, in 3 axes |
|
| Shock resistance |
| DIN EN 60068-2-27 Ea | 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes |
|
| Continuous shock resistance |
| DIN EN 60068-2-29 Eb | 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes |
|
| Fast temperature changes |
| DIN EN 60068-2-14 Na | TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles |
|
| Salt spray test |
| DIN EN 60068-2-11 Ka | 8 test cycles |
|
| Electrical safety |
| DIN EN 61010-2-201 | electric shock / electrical supply only via SELV/PELV circuits |
|
| MTTF |
56 |
| UL approval |
| Ta | -40...65 °C | | File number UL | E205959 |
|
| Weight |
428.3 |
| Housing |
rectangular |
| Mounting |
flush mountable |
| Dimensions |
80 x 80 x 45 |
| Material |
housing: PA; radome: PEI; sealing: HNBR |
| Display |
| Power | 1x LED, green | | errors | 1x LED, red |
|
| Pack quantity |
1 pcs. |
|
Connector: 1 x M12; coding: A |