| Product characteristics |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
<table><tr><td>0...100 bar</td><td>0...10 MPa</td></tr></table> |
| Process connection |
threaded connection G 1/4 external thread Internal thread:M5 |
| Application |
|
| Application |
for industrial applications |
| Media |
liquids and gases |
| Medium temperature |
-25...80 |
| Min. bursting pressure |
<table><tr><td>1000 bar</td><td>100 MPa</td></tr></table> |
| Pressure rating |
<table><tr><td>200 bar</td><td>20 MPa</td></tr></table> |
| Type of pressure |
relative pressure |
| Electrical data |
|
| Operating voltage |
9.6...32 DC |
| Current consumption |
< 25 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
switching signal |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
complementary |
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
500 |
| Switching frequency DC |
100 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>0...100 bar</td><td>0...10 MPa</td></tr></table> |
| Set point SP |
<table><tr><td>5...100 bar</td><td>0.5...10 MPa</td></tr></table> |
| Reset point rP |
<table><tr><td>3...98 bar</td><td>0.3...9.8 MPa</td></tr></table> |
| Accuracy / deviations |
|
| Switch point accuracy |
< ± 2,5; (Setting accuracy) |
| Repeatability |
< ± 0,5; (with temperature fluctuations < 10 K) |
| Characteristics deviation |
< ± 1,5 (BFSL) / < ± 2,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Temperature drift per 10 K |
< ± 0.5 |
| Software / programming |
|
| Adjustment of the switch point |
setting rings |
| Operating conditions |
|
| Ambient temperature |
-25...80 |
| Storage temperature |
-40...100 |
| Protection |
IP 67 |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table> |
| Shock resistance |
<table><tr><td>DIN IEC 68-2-27</td><td>50 g (11 ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN IEC 68-2-6</td><td>20 g (10...2000 Hz)</td></tr></table> |
| MTTF |
713 |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical data |
|
| Weight |
94.5 |
| Housing |
tubular |
| Dimensions |
Ø 27 / L = 71.6 |
| Material |
PBT; PC; FKM; stainless steel (1.4404 / 316L) |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); FKM |
| Min. pressure cycles |
50 million |
| Tightening torque |
25 |
| Process connection |
threaded connection G 1/4 external thread Internal thread:M5 |
| Restrictor element integrated |
no (can be retrofitted) |
| Displays / operating elements |
|
| Display |
<table><tr><td>Power</td><td>LED, green</td></tr><tr><td>Switching status</td><td>LED, yellow</td></tr></table> |
| With scale |
yes |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A |