Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

PK6222 – фото
Фото
Видео

На PK6222

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output signal switching signal
Medium temperature -25...80
Measuring range 0...100
Electrical design PNP
Process connection 1/4" NPT external thread

Все характеристики

Number of inputs and outputs Number of digital outputs: 2
Measuring range
0...100 bar0...1450 psi
Process connection threaded connection 1/4" NPT external thread Internal thread:M5
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure
1000 bar14500 psi100 MPa
Pressure rating
200 bar2900 psi20 MPa
Type of pressure relative pressure
Operating voltage 9.6...32 DC
Current consumption < 25
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Number of inputs and outputs Number of digital outputs: 2
Total number of outputs 2
Output signal switching signal
Electrical design PNP
Number of digital outputs 2
Output function complementary
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 500
Switching frequency DC 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring range
0...100 bar0...1450 psi
Set point SP
5...100 bar75...1450 psi
Reset point rP
3...98 bar50...1420 psi
Switch point accuracy < ± 2,5; (Setting accuracy)
Repeatability < ± 0,5; (with temperature fluctuations < 10 K)
Characteristics deviation < ± 1,5 (BFSL) / < ± 2,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Temperature drift per 10 K < ± 0.5
Adjustment of the switch point setting rings
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN IEC 68-2-2750 g (11 ms)
Vibration resistance
DIN IEC 68-2-620 g (10...2000 Hz)
MTTF 713
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 93
Housing tubular
Dimensions Ø 27 / L = 70.6
Material PBT; PC; FKM; stainless steel (1.4404 / 316L)
Materials (wetted parts) stainless steel (1.4404 / 316L)
Min. pressure cycles 50 million
Process connection threaded connection 1/4" NPT external thread Internal thread:M5
Restrictor element integrated no (can be retrofitted)
Display
PowerLED, green
Switching statusLED, yellow
With scale yes
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A

Приемущества

Simple switch point setting by means of two setting rings allowing optimum reading
High long-term stability thanks to robust stainless steel measuring cell with high permissible pressure rating
Mechanical locking prevents inadvertent switch point manipulation
Lifespan of more than 50 million pressure cycles
For use in hydraulics, pneumatics, air-conditioning and refrigeration