Cable material FEP
Approval CE, DNV, IECEx, UKCA
Measuring range 0...100.4
Cable length 5

Все характеристики

Number of inputs and outputs Number of analog outputs: 1
Measuring range
0...0.25 bar0...250 mbar0...3.63 psi0...100.4 inH2O0...25 kPa
Application for industrial applications
Media Liquids
Medium temperature -10...60; (T6: -10...60 °C; T5: -10...80 °C; T4: -10...85 °C; 1 D, 1/2 D, 2 D (750 mW): -10...40 °C; (650 mW): -10...70 °C; (550 mW): -10...85 °C)
Min. bursting pressure
2.4 bar35 psi240 kPa
Pressure rating
2 bar29 psi200 kPa
Type of pressure relative pressure
Switching amplifiers Connection to intrinsically safe supply isolators (Ex ia)
Operating voltage 10...30 DC
Protection class III
Reverse polarity protection yes
Number of inputs and outputs Number of analog outputs: 1
Total number of outputs 1
Output signal analog signal
Number of analog outputs 1
Analog current output 4...20
Max. load 700; (Ub = 24 V; (Ub - 10 V) / 20 mA)
Short-circuit protection yes
Measuring range
0...0.25 bar0...250 mbar0...3.63 psi0...100.4 inH2O0...25 kPa
Repeatability < 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation < 0,25 (BFSL) / 0,5; (incl. linearity, zero and span error (limit value setting); BFSL = Best Fit Straight Line)
Linearity deviation < 0,2 (BFSL)
Long-term stability < 0,2; (per year)
Temperature coefficient zero point < ± 0,2; (0...50 °C)
Temperature coefficient span < ± 0,2; (0...50 °C)
Ambient temperature -10...60
Note on ambient temperature
T6: -10...60 °C
T5: -10...80 °C
T4: -10...85 °C
1 D, 1/2 D, 2 D (750 mW): -10...40 °C
1 D, 1/2 D, 2 D (650 mW): -10...70 °C
1 D, 1/2 D, 2 D (550 mW): -10...85 °C
Storage temperature -10...60
Protection IP 68
Approval BVS 10 ATEX E 132 X; IECEx BVS 10.0085 X
ATEX marking I M1 Ex ia I Ma
II 1D Ex ia IIIC T135°C Da
MTTF 969
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 660.2
Housing tubular
Dimensions Ø 27 / L = 147
Material stainless steel (1.4571/316Ti )
Pack quantity 1 pcs.
Connection Cable: 5 m, FEP, Ø 7.5 mm

Приемущества

For level measurement in hazardous areas
Longitudinally watertight cable
Robust stainless steel housing with high ingress resistance
High overall accuracy and long-term stability