Характеристики

Output signal switching signal; analog signal; IO-Link
Measuring range -2...40.15
Medium temperature -25...150
Electrical design PNP/NPN
Process connection G 1 external thread sealing cone

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>-0.005...0.1 bar</td><td>-5...100 mbar</td><td>-2...40.15 inH2O</td><td>-0.5...10 kPa</td></tr></table>
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Application
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature -25...150
Min. bursting pressure <table><tr><td>30000 mbar</td><td>12044 inH2O</td><td>3000 kPa</td></tr></table>
Pressure rating <table><tr><td>4000 mbar</td><td>1606 inH2O</td><td>400 kPa</td></tr></table>
Vacuum resistance <table><tr><td>-1000 mbar</td><td>-0.1 MPa</td></tr></table>
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications according to CRN) 4
Electrical data
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Step response time analog output 30
3-wire
Min. response time of switching output (dAP) 3
Step response time analog output 7
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>-0.005...0.1 bar</td><td>-5...100 mbar</td><td>-2...40.15 inH2O</td><td>-0.5...10 kPa</td></tr></table>
Set point SP <table><tr><td>-0.0049...0.1 bar</td><td>-4.9...100 mbar</td><td>-1.95...40.15 inH2O</td><td>-0.49...10 kPa</td></tr></table>
Reset point rP <table><tr><td>-0.005...0.099 bar</td><td>-5...99.9 mbar</td><td>-2.01...40.09 inH2O</td><td>-0.5...9.99 kPa</td></tr></table>
Analog start point <table><tr><td>-0.005...0.08 bar</td><td>-5...80 mbar</td><td>-2.01...32.12 inH2O</td><td>-0.5...8 kPa</td></tr></table>
Analog end point <table><tr><td>0.015...0.1 bar</td><td>15...100 mbar</td><td>6.02...40.15 inH2O</td><td>1.5...10 kPa</td></tr></table>
Min. difference between SP and rP <table><tr><td>0.0002 bar</td><td>0.2 mbar</td><td>0.06 inH2O</td><td>0.02 kPa</td></tr></table>
In steps of <table><tr><td>0.0001 bar</td><td>0.1 mbar</td><td>0.01 inH2O</td><td>0.01 kPa</td></tr></table>
Factory setting <table><tr><td></td><td>SP1 =25 mbar</td><td>rP1 = 23 mbar</td></tr><tr><td></td><td>SP2 = 75 mbar</td><td>rP2 = 73 mbar</td></tr><tr><td></td><td>ASP = 0 mbar</td><td>AEP = 100 mbar</td></tr><tr><td></td><td>dAP = 2.00 s</td><td>dAA =2.00 s</td></tr></ta
Temperature monitoring
Accuracy ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability ± 0,2
Resolution 0.2
Accuracy / deviations
Switch point accuracy < ± 0,5; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability < ± 0,2; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,5; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation < ± 0,25; (Turn down 1:1)
Hysteresis deviation < ± 0,2; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range <table><tr><th>Temperature range</th><th>total deviation</th></tr><tr><td>-25...15 °C</td><td>Characteristics deviation ± 0,15 % of the span / 10 K</td></tr><tr><td>15...80 °C</td><td>Characteristics deviation</td></tr><tr><td>80...150 °C</td><td>Characte
Notes on the accuracy / deviation for further details see section Diagrams and graphs
Reaction times
Damping process value dAP 0...99.99
Damping for the analog output dAA 0...99.99
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Measurement data, high resolution</td></tr></table>
SIO mode yes
Required master port class A
Min. process cycle time 5.6
IO-Link resolution pressure 0.005
IO-Link resolution temperature 0.2
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>pressure</td><td>32</td></tr><tr><td>temperature</td><td>32</td></tr><tr><td>device status</td><td>4</td></tr><tr><td>binary switching information</td><td>2</td></tr></table>
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1158</td></tr></table>
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC <table><tr><td>DIN EN 61326-1</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>20 g (10...2000 Hz)</td></tr></table>
MTTF 214
Note on approval <table><tr><td> Factory certificate available as download at www.factory-certificate.ifm</td></tr></table>
UL approval <table><tr><td>UL approval number</td><td>J049 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Mechanical data
Weight 384.8
Housing tubular
Dimensions Ø 50 / L = 106
Material stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE
Min. pressure cycles 100 million
Tightening torque 20
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Displays / operating elements
Display <table><tr><td>Display unit</td><td>LED, green</td></tr><tr><td>Switching status</td><td>LED, yellow</td></tr><tr><td>Function display</td><td>alphanumeric display, 4-digit</td></tr><tr><td>Measured values</td><td>alphanumeric display, 4-digit</td></tr></
Display unit mbar; kPa; inH2O
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Robust stainless steel design for the requirements of the food and beverage industry
Hygienic, flush design
Resistant to high-pressure cleaning with aggressive cleaning agents
High temperature resistance and high protection rating
Programmable analog and switching output
Integrated temperature measurement via IO-Link
Convenient operation via buttons or parameter setting via IO-Link