| Product characteristics |
|
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range |
<table><tr><td>-1...16 bar</td><td>-14.6...232 psi</td><td>-0.1...1.6 MPa</td></tr></table> |
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Application |
|
| System |
gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature |
-25...150 |
| Min. bursting pressure |
<table><tr><td>250 bar</td><td>3625 psi</td><td>25 MPa</td></tr></table> |
| Pressure rating |
<table><tr><td>75 bar</td><td>1085 psi</td><td>7.5 MPa</td></tr></table> |
| Vacuum resistance |
<table><tr><td>-1000 mbar</td><td>-0.1 MPa</td></tr></table> |
| Type of pressure |
relative pressure; vacuum |
| No dead space |
yes |
| MAWP (for applications according to CRN) |
50 |
| Electrical data |
|
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
| 2-wire |
|
| Step response time analog output |
30 |
| 3-wire |
|
| Min. response time of switching output (dAP) |
3 |
| Step response time analog output |
7 |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; IO-Link |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Number of analog outputs |
1 |
| Analog current output |
4...20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>-1...16 bar</td><td>-14.6...232 psi</td><td>-0.1...1.6 MPa</td></tr></table> |
| Set point SP |
<table><tr><td>-0.98...16 bar</td><td>-14.2...232.1 psi</td><td>-0.098...1.6 MPa</td></tr></table> |
| Reset point rP |
<table><tr><td>-1...15.98 bar</td><td>-14.5...231.7 psi</td><td>-0.1...1.598 MPa</td></tr></table> |
| Analog start point |
<table><tr><td>-1...12.8 bar</td><td>-14.5...185.6 psi</td><td>-0.1...1.28 MPa</td></tr></table> |
| Analog end point |
<table><tr><td>2.2...16 bar</td><td>31.9...232.1 psi</td><td>0.22...1.6 MPa</td></tr></table> |
| Min. difference between SP and rP |
<table><tr><td>0.03 bar</td><td>0.4 psi</td><td>0.003 MPa</td></tr></table> |
| In steps of |
<table><tr><td>0.01 bar</td><td>0.1 psi</td><td>0.001 MPa</td></tr></table> |
| Factory setting |
<table><tr><td></td><td>SP1 = 4.00bar</td><td>rP1 = 3.68 bar</td></tr><tr><td></td><td>SP2 = 12.00 bar</td><td>rP2 = 11.68 bar</td></tr><tr><td></td><td>ASP = 0.00 bar</td><td>AEP = 16.00 bar</td></tr><tr><td></td><td>dAP = 0.06 s</td><td>dAA = 0.06 s</td |
| Temperature monitoring |
|
| Accuracy |
± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur )) |
| Repeatability |
± 0,2 |
| Resolution |
0.2 |
| Accuracy / deviations |
|
| Switch point accuracy |
< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1) |
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation |
< ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation |
< ± 0,15; (Turn down 1:1) |
| Long-term stability |
< ± 0,1; (Turn down 1:1; per year) |
| Total deviation over temperature range |
<table><tr><th>Temperature range</th><th>total deviation</th></tr><tr><td>-25...15 °C</td><td>Characteristics deviation ± 0,05 % of the span / 10 K</td></tr><tr><td>15...80 °C</td><td>Characteristics deviation</td></tr><tr><td>80...150 °C</td><td>Characte |
| Notes on the accuracy / deviation |
for further details see section Diagrams and graphs |
| Reaction times |
|
| Damping process value dAP |
0...99.99 |
| Damping for the analog output dAA |
0...99.99 |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
<table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Measurement data, high resolution</td></tr></table> |
| SIO mode |
yes |
| Required master port class |
A |
| Min. process cycle time |
5.6 |
| IO-Link resolution pressure |
0.0005 |
| IO-Link resolution temperature |
0.2 |
| IO-Link process data (cyclical) |
<table><tr><th>Function</th><th>bit length</th></tr><tr><td>pressure</td><td>32</td></tr><tr><td>temperature</td><td>32</td></tr><tr><td>device status</td><td>4</td></tr><tr><td>binary switching information</td><td>2</td></tr></table> |
| IO-Link functions (acyclical) |
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1147</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
-25...80 |
| Storage temperature |
-40...100 |
| Protection |
IP 67; IP 68; IP 69K |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN EN 61326-1</td><td></td></tr></table> |
| Shock resistance |
<table><tr><td>DIN EN 60068-2-27</td><td>50 g (11 ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN EN 60068-2-6</td><td>20 g (10...2000 Hz)</td></tr></table> |
| MTTF |
214 |
| Note on approval |
<table><tr><td> Factory certificate available as download at www.factory-certificate.ifm</td></tr></table> |
| UL approval |
<table><tr><td>UL approval number</td><td>J048 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table> |
| Mechanical data |
|
| Weight |
357.8 |
| Housing |
tubular |
| Dimensions |
Ø 50 / L = 107 |
| Material |
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE |
| Min. pressure cycles |
100 million |
| Tightening torque |
35 |
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Displays / operating elements |
|
| Display |
<table><tr><td>Display unit</td><td>LED, green</td></tr><tr><td>Switching status</td><td>LED, yellow</td></tr><tr><td>Function display</td><td>alphanumeric display, 4-digit</td></tr><tr><td>Measured values</td><td>alphanumeric display, 4-digit</td></tr></ |
| Display unit |
bar; psi; MPa |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |