| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
| -1...0 bar | -1000...0 mbar | -100...0 kPa |
|
| Process connection |
threaded connection G 1/8 Internal thread (2x) |
| System |
gold-plated contacts |
| Application |
for industrial applications |
| Media |
compressed air; nitrogen (N2) |
| Conditionally suitable for |
other media on request |
| Medium temperature |
0...60 |
| Min. bursting pressure |
|
| Pressure rating |
|
| Vacuum resistance |
|
| Type of pressure |
relative pressure; vacuum |
| Operating voltage |
18...30 DC |
| Current consumption |
< 30 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Overvoltage protection |
yes; (< 40 V) |
| Power-on delay time |
0.3 |
| Integrated watchdog |
yes |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Total number of outputs |
2 |
| Output signal |
switching signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN; (configurable) |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2.5 |
| Permanent current rating of switching output DC |
100 |
| Switching frequency DC |
< 170 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring range |
| -1...0 bar | -1000...0 mbar | -100...0 kPa |
|
| Set point SP |
|
| In steps of |
| 0.001 bar | 0.1 kPa | 0.0001 MPa |
|
| Switch point accuracy |
< ± 1 |
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K:) |
| Characteristics deviation |
< ± 1; (including linearity, hysteresis and repeatability) |
| Linearity deviation |
< ± 1 % (limit value setting to DIN EN IEC 62828-1) |
| Hysteresis deviation |
< ± 0,25 |
| Long-term stability |
< ± 0,1; (per year) |
| Temperature coefficient zero point |
0,2 |
| Temperature coefficient span |
0,2 |
| Response time |
6 |
| Damping process value dAP |
0...4 |
| Damping for the analog output dAA |
0...99.99 |
| Parameter setting options |
display can be rotated and switched off; Teach function; simulation function; Diagnostic function |
| Communication interface |
IO-Link |
| Transmission type |
COM3 (230,4 kBaud) |
| IO-Link revision |
1.1.3 |
| SDCI standard |
IEC 61131-9: 2019-06 |
| Profiles |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel | | BLOB | Binary Large Object transfer | | Common - I&D | Identification and Diagnosis | | Extension | Quantity detection, switches when value exceeds the setpoint | | Function | Locator | | Function | ProductURI |
|
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
1 |
| Process data binary |
2 |
| Min. process cycle time |
0.6 |
| IO-Link resolution pressure |
0.0001 |
| IO-Link process data (cyclical) |
| Function | bit length |
|---|
| pressure | 16 | | device status | 4 | | SSC1.1 | 1 | | SSC1.2 | 1 |
|
| IO-Link functions (acyclical) |
application specific tag; internal temperature; Medium temperature |
| Supported DeviceIDs |
| Type of operation | DeviceID |
|---|
| default | 1745 |
|
| Ambient temperature |
0...60 |
| Storage temperature |
-25...85 |
| Protection |
IP 65 |
| EMC |
|
| Shock resistance |
| DIN EN 60068-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| MTTF |
508 |
| UL approval |
|
| Pressure equipment directive |
sound engineering practice; can be used for stable gases fluid group 2 |
| Weight |
53.05 |
| Housing |
rectangular |
| Dimensions |
37.7 x 30 x 38.6 |
| Material |
PBT; PC; TPE; NBR; FKM; brass; silicon (coated) |
| Materials (wetted parts) |
PBT; FKM; brass; silicon (coated) |
| Min. pressure cycles |
50 million |
| Process connection |
threaded connection G 1/8 Internal thread (2x) |
| Display |
| Display 1" | 128 x 96 pixels | | Switching status | 2 x LED, yellow |
|
| Display unit |
mbar; kPa; mmHg; kgf/cm² |
| Items supplied |
| head cap screw: 2 x (M3 x 8 mm) |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M8; coding: A; Contacts: gold-plated |