Output signal analog signal; IO-Link
Measuring range -1...16
Medium temperature -25...110; (flush mount zero-leak using metal-to-metal seal. For permissible temperatures of other sealing versions, see sealing materials under “Accessories”)
Process connection G 1/2 external thread

Все характеристики

Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
-1...16 bar-14.5...232 psi-0.1...1.6 MPa
Process connection threaded connection G 1/2 external thread
System gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Temperature monitoring yes
Application Industrial flush pressure transmitters, analog | PL; for industrial applications
Media viscous media and liquids with suspended particles; Liquids; other media on request
Medium temperature -25...110; (flush mount zero-leak using metal-to-metal seal. For permissible temperatures of other sealing versions, see sealing materials under “Accessories”)
Min. bursting pressure
250 bar3625 psi25 MPa
Pressure rating
100 bar1450 psi10 MPa
Vacuum resistance -1000
Type of pressure relative pressure; vacuum
No dead space yes
Operating voltage 9.6...30 DC
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
Step response time analog output 12
Step response time analog output 3
Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Total number of outputs 2
Output signal analog signal; IO-Link
Number of digital outputs 1; (IO-Link)
Number of analog outputs 1
Analog current output 4...20; (scalable; 1:5)
Max. load (Ub - 9,6 V) / 21,5 mA; 670 Ω (Ub = 24 V)
Short-circuit proof yes
Overload protection yes
Measuring range
-1...16 bar-14.5...232 psi-0.1...1.6 MPa
Analog start point
-1...14 bar-14.5...203.1 psi-0.1...1.4 MPa
Analog end point
1...16 bar14.5...232.1 psi0.1...1.6 MPa
In steps of
0.002 bar0.2 psi0.0002 MPa
Factory setting
ASP = 0.0 barAEP = 16.0 bar
ASP = 0.0 psiAEP = 232.1 psi
ASP = 0.0 MPaAEP = 1.6 MPa
Accuracy ± 2.5 K + (0.045 x (ambient temperature - medium temperature))
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity deviation < ± 0,15; (Turn down 1:1)
Hysteresis deviation < ± 0,15; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point < ± 0,1 (-25...85 °C) < ± 0,3 (85...110 °C)
Temperature coefficient span < ± 0,1 (-25...85 °C) < ± 0,3 (85...110 °C)
Damping process value dAP 0...99.99
Damping for the analog output dAA 0...99.99
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO mode no
Required master port class A; (when pin 2 not connected: B)
Min. process cycle time 3.5
IO-Link resolution pressure 0.002
IO-Link resolution temperature 0.2
IO-Link process data (cyclical)
Functionbit length
pressure16
temperature16
device status4
IO-Link functions (acyclical) application specific tag; internal temperature
Supported DeviceIDs
Type of operationDeviceID
default1490
Ambient temperature -25...90
Storage temperature -40...100
Protection IP 67; IP 68; IP 69
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 427
Embedded software included yes
UL approval
Enclosure typeType 1
UL approval numberJ050
File number ULE174189
Weight 114
Housing tubular
Dimensions Ø 30 / L = 63
Material stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); PA; PTFE; FKM
Materials (wetted parts) stainless steel (1.4435 / 316L); Al2O3 (ceramics) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE; (FKM for sealing with seal DIN EN ISO 1179-2, see operating instructions)
Min. pressure cycles 100 million
Tightening torque 25
Process connection threaded connection G 1/2 external thread
Display
operating status2 LED, green
Items supplied
Gasket: G1/2, FKM DIN EN ISO1179-2 (-15...110°C), E30492
Accessories (optional)
Gasket: G1/2, FKM DIN EN ISO1179-2 (-15...110°C), E30492
Gasket: G1/2, EPDM DIN EN ISO1179-2 (-25...110°C), E30451
Gasket: G1/2, FFKM DIN EN ISO1179-2 (-5...110°C), E30513
O-ring: 16,4 x 1, FKM (-15...110°C), E30510
O-ring: 16,4 x 1, EPDM (-25...110°C), E30511
O-ring: 16,4 x 1, FFKM (-5...110°C), E30512
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Reliable detection of system pressure in industrial and mobile applications
High shock and vibration resistance
Excellent repeatability and low linearity error
Compact and robust stainless steel housing for use where space is restricted
Integrated temperature measurement via IO-Link
Precise analog output and user-friendly communication via IO-Link