| Product characteristics |
|
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range |
<table><tr><td>-1...10 bar</td><td>-14.5...145 psi</td><td>-0.1...1 MPa</td></tr></table> |
| Process connection |
Clamp DN40 (1,5") DIN 32676 (ISO 2852) electropolished |
| Application |
|
| System |
gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature |
-20...200; (-20...90 < 0 bar) |
| Min. bursting pressure |
<table><tr><td>100 bar</td><td>1450 psi</td><td>10 MPa</td></tr></table> |
| Pressure rating |
<table><tr><td>50 bar</td><td>725 psi</td><td>5 MPa</td></tr></table> |
| Type of pressure |
relative pressure; vacuum |
| Electrical data |
|
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
| 2-wire |
|
| Step response time analog output |
45 |
| 3-wire |
|
| Min. response time of switching output (dAP) |
3 |
| Step response time analog output |
7 |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Number of analog outputs |
1 |
| Analog current output |
4...20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>-1...10 bar</td><td>-14.5...145 psi</td><td>-0.1...1 MPa</td></tr></table> |
| Set point SP |
<table><tr><td>-0.98...10 bar</td><td>-14.2...145 psi</td><td>-0.098...1 MPa</td></tr></table> |
| Reset point rP |
<table><tr><td>-1...9.98 bar</td><td>-14.5...144.7 psi</td><td>-0.1...0.998 MPa</td></tr></table> |
| Analog start point |
<table><tr><td>-1...7.5 bar</td><td>-14.5...108.7 psi</td><td>-0.1...0.75 MPa</td></tr></table> |
| Analog end point |
<table><tr><td>1.5...10 bar</td><td>21.8...145 psi</td><td>0.15...1 MPa</td></tr></table> |
| In steps of |
<table><tr><td>0.01 bar</td><td>0.1 psi</td><td>0.001 MPa</td></tr></table> |
| Factory setting |
<table><tr><td></td><td>SP1 = 2.50 bar</td><td>rP1 = 2.30 bar</td></tr><tr><td></td><td>SP2 = 7.50 bar</td><td>rP2 = 7.30 bar</td></tr><tr><td></td><td>ASP = 0.00 bar</td><td>AEP = 10.00 bar</td></tr></table> |
| Accuracy / deviations |
|
| Switch point accuracy |
< ± 0,2; (Turn down 1:1) |
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation |
< ± 0,15; (Turn down 1:1) |
| Long-term stability |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point |
< ± 0,2; (0...200 °C) |
| Temperature coefficient span |
< ± 0,15; (0...200 °C) |
| Reaction times |
|
| Damping process value dAP |
0...30 |
| Damping for the analog output dAA |
0.01...99.99 |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.0 |
| SDCI standard |
IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 |
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
1 |
| Process data binary |
2 |
| Min. process cycle time |
2.3 |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>157</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
-25...65 |
| Note on ambient temperature |
<table><tr><td>Medium temperature: ≤ 200 °C</td></tr></table> |
| Storage temperature |
-25...100 |
| Protection |
IP 67; IP 68; IP 69K |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table> |
| Shock resistance |
<table><tr><td>DIN EN 60068-2-27</td><td>50 g (11 ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN EN 60068-2-6</td><td>20 g (10...2000 Hz)</td></tr></table> |
| Note on approval |
<table><tr><td> Including free 6-point calibration certificate.</td></tr></table> |
| Mechanical data |
|
| Weight |
1056.6 |
| Housing |
tubular |
| Dimensions |
Ø 50 / L = 163 |
| Material |
stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA |
| Materials (wetted parts) |
stainless steel (1.4435 / 316L) |
| Min. pressure cycles |
10 million |
| Process connection |
Clamp DN40 (1,5") DIN 32676 (ISO 2852) electropolished |
| Surface characteristics Ra/Rz of the wetted parts |
Ra < 0.38 µm |
| Fill fluid for pressure transfer |
NEOBEE (food grade, FDA compliant) |
| Diaphragm diameter |
34 |
| Displays / operating elements |
|
| Display |
<table><tr><td>Display unit</td><td>LED, green</td></tr><tr><td>Switching status</td><td>LED, yellow</td></tr><tr><td>Function display</td><td>alphanumeric display, 4-digit</td></tr><tr><td>Measured values</td><td>alphanumeric display, 4-digit</td></tr></ |
| Display unit |
bar; psi; MPa; % of the span |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|