Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

PI2214 – фото
Фото
Видео

На PI2214

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output signal switching signal; analog signal; IO-Link; (configurable)
Measuring range -1...10
Medium temperature -20...200; (-20...90 < 0 bar)
Electrical design PNP/NPN
Process connection Clamp DN40 (1,5")

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>-1...10 bar</td><td>-14.5...145 psi</td><td>-0.1...1 MPa</td></tr></table>
Process connection Clamp DN40 (1,5") DIN 32676 (ISO 2852) electropolished
Application
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature -20...200; (-20...90 < 0 bar)
Min. bursting pressure <table><tr><td>100 bar</td><td>1450 psi</td><td>10 MPa</td></tr></table>
Pressure rating <table><tr><td>50 bar</td><td>725 psi</td><td>5 MPa</td></tr></table>
Type of pressure relative pressure; vacuum
Electrical data
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Step response time analog output 45
3-wire
Min. response time of switching output (dAP) 3
Step response time analog output 7
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>-1...10 bar</td><td>-14.5...145 psi</td><td>-0.1...1 MPa</td></tr></table>
Set point SP <table><tr><td>-0.98...10 bar</td><td>-14.2...145 psi</td><td>-0.098...1 MPa</td></tr></table>
Reset point rP <table><tr><td>-1...9.98 bar</td><td>-14.5...144.7 psi</td><td>-0.1...0.998 MPa</td></tr></table>
Analog start point <table><tr><td>-1...7.5 bar</td><td>-14.5...108.7 psi</td><td>-0.1...0.75 MPa</td></tr></table>
Analog end point <table><tr><td>1.5...10 bar</td><td>21.8...145 psi</td><td>0.15...1 MPa</td></tr></table>
In steps of <table><tr><td>0.01 bar</td><td>0.1 psi</td><td>0.001 MPa</td></tr></table>
Factory setting <table><tr><td></td><td>SP1 = 2.50 bar</td><td>rP1 = 2.30 bar</td></tr><tr><td></td><td>SP2 = 7.50 bar</td><td>rP2 = 7.30 bar</td></tr><tr><td></td><td>ASP = 0.00 bar</td><td>AEP = 10.00 bar</td></tr></table>
Accuracy / deviations
Switch point accuracy < ± 0,2; (Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation < ± 0,15; (Turn down 1:1)
Hysteresis deviation < ± 0,15; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point < ± 0,2; (0...200 °C)
Temperature coefficient span < ± 0,15; (0...200 °C)
Reaction times
Damping process value dAP 0...30
Damping for the analog output dAA 0.01...99.99
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
SDCI standard IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002
SIO mode yes
Required master port class A
Process data analog 1
Process data binary 2
Min. process cycle time 2.3
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>157</td></tr></table>
Operating conditions
Ambient temperature -25...65
Note on ambient temperature <table><tr><td>Medium temperature: ≤ 200 °C</td></tr></table>
Storage temperature -25...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>20 g (10...2000 Hz)</td></tr></table>
Note on approval <table><tr><td> Including free 6-point calibration certificate.</td></tr></table>
Mechanical data
Weight 1056.6
Housing tubular
Dimensions Ø 50 / L = 163
Material stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 10 million
Process connection Clamp DN40 (1,5") DIN 32676 (ISO 2852) electropolished
Surface characteristics Ra/Rz of the wetted parts Ra < 0.38 µm
Fill fluid for pressure transfer NEOBEE (food grade, FDA compliant)
Diaphragm diameter 34
Displays / operating elements
Display <table><tr><td>Display unit</td><td>LED, green</td></tr><tr><td>Switching status</td><td>LED, yellow</td></tr><tr><td>Function display</td><td>alphanumeric display, 4-digit</td></tr><tr><td>Measured values</td><td>alphanumeric display, 4-digit</td></tr></
Display unit bar; psi; MPa; % of the span
Remarks
Pack quantity 1 pcs.
Electrical connection

Приемущества

For use in high temperatures in the food and beverage industry
Robust stainless steel housing with hygienic front-flush design
With two-wire and three-wire connection technology
Reduced wiring complexity when operated as two-wire current loop
Integrated clamp diaphragm seal with stainless steel membrane
Convenient operation via buttons or parameter setting via IO-Link