| Product characteristics |
|
| Type of light |
red light |
| Laser protection class |
1 |
| Housing |
rectangular |
| Electrical data |
|
| Operating voltage |
10...30 DC; (cULus - Class 2 source required) |
| Current consumption |
< 200; (10 V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
2 |
| Type of light |
red light |
| Wave length |
650 |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital inputs: 1; Number of digital outputs: 2 |
| Inputs |
|
| Trigger |
external |
| Number of digital inputs |
1 |
| Outputs |
|
| Electrical design |
PNP/NPN; (configurable) |
| Number of digital outputs |
2 |
| Output function |
2 x normally open / normally closed; (configurable) |
| Max. current load per output |
100 |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
|
| Measuring distance (Z-direction) |
150...300 |
| Width of the measuring range (X-direction) at min. measuring distance |
45; (distance = 150mm) |
| Width of the measuring range (X-direction) at max. measuring distance |
90; (distance = 300mm) |
| Sampling rate |
5 |
| Accuracy / deviations |
|
| Measured value resolution |
<table><tr><td>Z-direction 200 µm</td></tr><tr><td>X-direction 250 µm</td></tr></table> |
| Accuracy |
<table><tr><td>Z-direction ± 500 µm</td></tr><tr><td>X-direction ± 500 µm</td></tr><tr><td>Background white (90 % remission) </td></tr></table> |
| Software / programming |
|
| Number of profiles which can be stored |
1 |
| Number of regions of interest |
1 |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM3 (230,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
<table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Multiple switching signal</td></tr><tr><td>Function</td><td>Measurement data, standard resolution</td></tr></table> |
| SIO mode |
yes |
| Required master port class |
A |
| Min. process cycle time |
2.3 |
| IO-Link process data (cyclical) |
<table><tr><th>Function</th><th>bit length</th></tr><tr><td>process value</td><td>16</td></tr><tr><td>device status</td><td>4</td></tr><tr><td>binary switching information</td><td>1</td></tr></table> |
| IO-Link functions (acyclical) |
operating hours counter; number of trigger events; ROI setting |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1260</td></tr></table> |
| Note |
<table><tr><td> For further information please see the IODD PDF file at "Downloads"</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
-10...55 |
| Storage temperature |
-40...60 |
| Protection |
IP 65 |
| Max. immunity to extraneous light |
20 |
| Tests / approvals |
|
| EMC |
<table><tr><td>EN 60947-5-2</td><td></td></tr></table> |
| Laser protection class |
1 |
| Notes on laser protection |
<table><tr><td>Caution:</td><td>Laser light</td></tr><tr><td>laser class:</td><td>1</td></tr><tr><td></td><td>EN / IEC60825-1:2007</td></tr><tr><td></td><td>EN / IEC60825-1:2014</td></tr><tr><td></td><td>Complies with 21 CFR 1040.10 except for conformance |
| MTTF |
155 |
| UL approval |
<table><tr><td>Ta</td><td>-10...55 °C</td></tr><tr><td>Enclosure type</td><td>Type 1 </td></tr><tr><td>voltage supply</td><td>Class 2 </td></tr><tr><td>File number UL</td><td>E174191 </td></tr></table> |
| Mechanical data |
|
| Weight |
535.8 |
| Housing |
rectangular |
| Dimensions |
88 x 28.5 x 65 |
| Material |
housing: diecast zinc; PPSU; ABS; PMMA; PBT / PC; EPDM; front lens: PMMA |
| Displays / operating elements |
|
| Display |
<table><tr><td>Switching status</td><td>1 x LED, yellow</td></tr><tr><td>Display operation</td><td>1 x LED, green</td></tr><tr><td></td><td>Color display</td></tr></table> |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A |