Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

OMH551 – фото
OMH551 – фото
OMH551 – фото
OMH551 – фото
Фото
Видео

На OMH551

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output function normally open / closed; (configurable); analog
Laser protection class 1
Dimensions 51 x 51 x 17
Product designation Laser distance sensor
Measuring range 0.03...0.08

Все характеристики

Type of light red light
Laser protection class 1
Housing rectangular
Operating voltage 18...30 DC; (cULus - Class 2 source required)
Current consumption < 30
Protection class III
Reverse polarity protection yes
Power-on delay time < 0.3
Type of light red light
Wave length 630
Typ. lifetime 50000
Number of inputs and outputs Number of digital inputs: 1; Number of digital outputs: 1; Number of analog outputs: 1
Inputs Laser On/ Off
Number of digital inputs 1
Total number of outputs 2
Electrical design PNP/NPN; (configurable)
Number of digital outputs 1
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.2
Permanent current rating of switching output DC 100
Switching frequency DC 200
Notes on switching frequency
standard
Number of analog outputs 1
Analog current output 4...20; (IEC61131-2)
Max. load 500
Analog voltage output 0...10; (IEC 61131-2)
Min. load resistance 5000
Short-circuit protection yes
Overload protection yes
Range adjustable yes
Max. light spot diameter 0.5
Light spot dimensions refer to at maximum range
Measuring range 0.03...0.08; (6...90% remission)
Temperature compensation yes
Repeatability 0.03
Linearity error of analog output ±0,1
Resolution 0,01
Notes on the accuracy / deviation The indicated values are reached after a warm-up time of 20 minutes.
Parameter setting options hysteresis / window / 2-point; Switch-on and switch-off delay; switch-on operations; Teach function; filter; light-on/dark-on mode; laser switch-off; Type of operation
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Smart Sensor - SSP 4.1.1Measuring and Switching Sensor, 1 channel
Common - I&DIdentification and Diagnosis
ExtensionSensor control
ExtensionTeach two point
FunctionLocator
FunctionProductURI
SIO mode yes
Required master port class A
Min. process cycle time 3.2
IO-Link process data (cyclical)
Functionbit length
process value16
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag; operating hours counter
Supported DeviceIDs
Type of operationDeviceID
default1606
Note
For further information please see the IODD PDF file at "Downloads"
Ambient temperature 0...60
Storage temperature -10...65
Protection IP 65; IP 67
EMC
EN 61000-4-2 ESD4 kV CD / plastics
8 kV AD / metal
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-6 HF conducted10 V
EN 61000-4-4 Burst2 kV
EN 55011class B
Vibration resistance
EN 60068-2-6 Fc(10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis with resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Laser protection class 1
Notes on laser protection
Caution:Laser light
laser class:1
EN/IEC 60825-1 2007
EN/IEC 60825-1 2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
MTTF 552
UL approval
voltage supplyClass 2
Weight 127.2
Housing rectangular
Dimensions 51 x 51 x 17
Material housing: diecast zinc; front lens: plastics
Tightening torque 5
Display
Switching status1 LED, yellow
supply voltage1 LED, green
Operating mode4 LED, white
Teach function yes
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A

Приемущества

Optical distance measurement in the micrometer range
Two switching outputs
Suitable for high-frequency applications
Three operating modes and a robust, compact design enable a wide range of applications
Visualization of the distance value via IO-Link
Convenient operation via buttons or parameter setting via IO-Link