| Product characteristics |
|
| Type of light |
red light |
| Laser protection class |
2 |
| Housing |
rectangular |
| Application |
|
| System |
Background suppression |
| Electrical data |
|
| Operating voltage |
10...30 DC; (cULus - Class 2 source required) |
| Current consumption |
75; (24 V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Type of light |
red light |
| Wave length |
650 |
| Typ. lifetime |
50000 |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Outputs |
|
| Total number of outputs |
2 |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (complementary) |
| Max. current load per output |
100 |
| Switching frequency DC |
11 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Monitoring range |
|
| Max. light spot diameter |
5 |
| Light spot dimensions refer to |
2 m |
| Detection range hysteresis |
< 2.5 |
| Note on monitoring range hysteresis |
<table><tr><td>black 6 % remission </td></tr></table> |
| Background suppression available |
yes |
| Background suppression |
< 20 |
| Measuring/setting range |
|
| Measuring range |
0.03...2 |
| Sampling rate |
33 |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
<table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Multiple switching signal</td></tr><tr><td>Function</td><td>Process data variable</td></tr></table> |
| SIO mode |
yes |
| Process data analog |
1 |
| Process data binary |
1 |
| Min. process cycle time |
6.4 |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>372</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
-25...60 |
| Note on ambient temperature |
<table><tr><td>at ta < -10 °C warm-up is necessary, laser is off </td></tr></table> |
| Protection |
IP 65; IP 67 |
| Max. immunity to extraneous light |
10; (on the object) |
| Tests / approvals |
|
| EMC |
<table><tr><td>EN 60947-5-2</td><td></td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN EN 60068-2-6</td><td>10 g (10...55 Hz) / 120 min. per axis (x, y, z)</td></tr></table> |
| Shock resistance |
<table><tr><td>DIN EN 60068-2-27</td><td>50 g 6 shocks / 11 ms half-sine (x, y, z)</td></tr></table> |
| Laser protection class |
2 |
| Notes on laser protection |
<table><tr><td>Caution:</td><td>Laser light</td></tr><tr><td>Power:</td><td><= 4,0 mW</td></tr><tr><td>Wave length:</td><td>650 nm</td></tr><tr><td>pulse:</td><td>1,3 ns</td></tr><tr><td>Do not stare into beam.</td><td></td></tr><tr><td>Avoid exposure to |
| MTTF |
151 |
| Mechanical data |
|
| Weight |
61.6 |
| Housing |
rectangular |
| Dimensions |
56 x 18.2 x 46.8 |
| Material |
housing: PA; Front framework: stainless steel; operator interface: TPU (urethane); lens: PMMA |
| Lens alignment |
Side sensing |
| Displays / operating elements |
|
| Display |
<table><tr><td>Switching status</td><td>LED, yellow Switching output PIN 4</td></tr><tr><td>Power</td><td>LED, green</td></tr><tr><td>Display</td><td>alphanumeric display, 3-digit</td></tr></table> |
| Display unit |
cm |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A |