Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

LI5134 – фото
LI5134 – фото
LI5134 – фото
Фото
Видео

На LI5134

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Probe length L 737
Electrical design PNP/NPN
Factory setting water-based media

Все характеристики

Number of inputs and outputs Number of digital outputs: 2
Factory setting water-based media
Probe length L 737
System gold-plated contacts
Media Liquids
Dielectric constant of the medium > 1,8
Recommended media water; water-based media; oils; oil-based media
Cannot be used for See operating instructions, chapter "Intended use".
Medium temperature -25...85
Pressure rating
0.5 bar0.05 MPa
Vacuum resistance -500
Operating voltage 9.6...35 DC; (IO-Link: 18...30 DC)
Current consumption < 15
Protection class III
Reverse polarity protection yes
Power-on delay time < 1
Measuring principle capacitive
Number of inputs and outputs Number of digital outputs: 2
Total number of outputs 2
Output signal switching signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Factory setting water-based media
Probe length L 737
Active range A 28
Accuracy 1,5
Resolution 0.1
Dynamic response T09 240
Response time < 0.3
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO mode yes
Required master port class A
Process data analog 5
Process data binary 2
Min. process cycle time 4.5
Supported DeviceIDs
Type of operationDeviceID
default1053
Ambient temperature -25...85
Storage temperature -25...85
Protection IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68)
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3in a closed metal tank
DIN EN 61000-6-4in plastic or open metal tanks
Shock resistance
DIN EN 60068-2-2712 g (11 ms)
Vibration resistance
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF 433
UL approval
UL approval numberH013
File number ULE174191
Weight 510.4
Material PP fiber-reinforced
Materials (wetted parts) PP
Probe diameter 16
Display
PowerLED, green
Switching statusLED, yellow
Operating elements
inductive programming button
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

For the reliable point level monitoring in tanks and containers
Detection of minimum level, leakage or overflow of tanks
simple empty or full adjustment
Suitable for water, oils and coolants
User-friendly setting of the requested immersion depth of the sensor
Integrated temperature measurement via IO-Link