Material housing: brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Measuring range 1...15
Protection IP 65, IP 66, IP 67, IP 68, IP 69K
Dimensions M30 x 1.5 / L = 65
Ambient temperature -25...80

Все характеристики

Electrical design PNP/NPN; (configurable)
Output function normally open / closed; (configurable)
Communication interface IO-Link
Housing Threaded type
Dimensions M30 x 1.5 / L = 65
Operating voltage 15...30 DC
Current consumption < 30
Protection class II
Reverse polarity protection yes
Electrical design PNP/NPN; (configurable)
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 100
Switching frequency DC 300
Analog current output 4...20; (linear; gradient: 1,143 mA/mm; for frontal approach and for target made of mild steel: 45 x 45 x 1 mm)
Max. load 500; (Ub <=18 V;; Max. load <=400 Ω)
Short-circuit protection yes
Overload protection yes
Measuring range 1...15
Switch point IO-Link 2.37...13.99
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.4 / copper: 0.3
Hysteresis 3...15
Note on hysteresis
configurable
Linearity error of analog output ± 1; (of the final value of the measuring range)
Repeatability analog output ± 1; (of the final value of the measuring range)
Temperature coefficient ±0,15
Temperature drift ± 5 %; (of the final value of the measuring range)
Response time < 10
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
Common - I&DIdentification and Diagnosis
FunctionMultiple switching signal
FunctionTeach channel
SIO mode yes
Required master port class A
Min. process cycle time 3.2
IO-Link process data (cyclical)
Functionbit length
process value16
device status4
binary switching information2
IO-Link functions (acyclical) switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag
Supported DeviceIDs
Type of operationDeviceID
default1205
Note
For further information please see the IODD PDF file at "Downloads"
Ambient temperature -25...80
Protection IP 65; IP 66; IP 67; IP 68; IP 69K
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
EN 55011class B
Vibration resistance
EN 60068-2-6 Fc20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-2740 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changes
EN 60068-2-14 NaTA = -25°C; TB = 80°C; t1 = 30 min; t2 = < 10 s 50 cycles
MTTF 522
Embedded software included yes
UL approval
Ta-25...60 °C
Enclosure typeType 1
voltage supplyLimited Voltage/Current
UL approval numberA023
File number ULE174191
Weight 113
Housing Threaded type
Mounting non-flush mountable
Dimensions M30 x 1.5 / L = 65
Thread designation M30 x 1.5
Material housing: brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Tightening torque 50
Display
target in measuring range4 x LED, yellow lights
target outside measuring range4 x LED, yellow flashing
Items supplied
lock nuts: 2
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A

Приемущества

Precise linearized output signal
Very high repeatability
For non-contact distance measurement
Wide operating temperature range
Robust metal housing for use in harsh industrial environments
User-friendly communication and parameterization via IO-Link