| Number of measurement axes |
1 |
| Angular range |
± 90 |
| Function principle |
static |
| Application |
Industrial applications; Mobile applications |
| Operating voltage |
8...30 DC |
| Current consumption |
< 35 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Number of inputs and outputs |
Number of analog outputs: 1 |
| Output signal |
analog signal; (see characteristics) |
| Number of analog outputs |
1 |
| Analog voltage output |
0.5...4.5 |
| Min. load resistance |
50000 |
| Overload protection |
yes |
| Number of measurement axes |
1 |
| Angular range |
± 90 |
| Repeatability |
0,1 |
| Ambient temperature |
-30...85 |
| Storage temperature |
-30...85 |
| Protection |
IP 67 |
| EMC |
| EN 61000-4-2 ESD | 4 kV | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 10 V | | EN 61000-6-3 noise emission | class B |
|
| Shock resistance |
| EN 60068-2-29 | 30 g 6 ms / 24000 shocks |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 10 g (10...500 Hz) / 10 frequency cycles in 3 axes | | DIN EN 60068-2-64 | (10...2000 Hz) / 32 hours in 3 axes |
|
| MTTF |
884 |
| Weight |
282 |
| Dimensions |
40.5 x 40.5 x 52.2 |
| Material |
housing: PPO |
| Tightening torque |
1.8 |
| Mounting orientation |
vertical |
| Pack quantity |
1 pcs. |
| Connection |
Cable: 3.5 m, PUR |