Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

SV7500 – фото
Фото
Видео

На SV7500

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output function normally open / closed; (configurable)
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Measuring range temperature -10...90 °C
Measuring range 0.3...6
Process connection Rc 3/4 Internal thread DN20

Все характеристики

Number of inputs and outputs Number of digital outputs: 2
Measuring range
5...100 l/min0.3...6 m³/h
Process connection threaded connection Rc 3/4 Internal thread DN20
System gold-plated contacts
Application for industrial applications
Media water; glycol solutions; Coolants
Medium temperature -10...90
Pressure rating
12 bar1.2 MPa
Note on pressure rating
up to 40 °C
Operating voltage 18...30 DC
Current consumption < 30
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time < 3
Measuring principle Vortex
Number of inputs and outputs Number of digital outputs: 2
Total number of outputs 2
Output signal switching signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 100
Short-circuit protection yes
Overload protection yes
Measuring range
5...100 l/min0.3...6 m³/h
Display range
0...120 l/min0...7.2 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
6...100 l/min0.36...6 m³/h
Reset point rP
5...99 l/min0.3...5.94 m³/h
Frequency end point, FEP
20...100 l/min1.2...6 m³/h
In steps of
0.5 l/min0.02 m³/h
Frequency at the end point FRP 100...1000
Measuring dynamics 1:20
Dynamic response T05 / T09 T09 = 6
Response time 1; (dAP = 0)
Damping process value dAP 0...5
Parameter setting options hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 3
Supported DeviceIDs
Type of operationDeviceID
default492
Ambient temperature 0...60
Note on ambient temperature
medium temperature < 80 °C
medium temperature < 90 °C: 0...50 °C
Storage temperature -20...80
Protection IP 65; IP 67
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
CPA approval
model number001VO
accuracy class-
maximum allowable error± 2 % FS
Q (min)0,36 m³/h
Q (t)1,2 m³/h
Q (max)6 m³/h
Shock resistance
DIN EN 60068-2-275 g (11 ms)
Vibration resistance
DIN EN 60068-2-6with water / 10...50 Hz 1 mm
with water / 50...2000 Hz 2 g
MTTF 342
UL approval
UL approval numberI001
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 487.5
Housing rectangular
Dimensions 135 x 45 x 72
Material stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque 30
Process connection threaded connection Rc 3/4 Internal thread DN20
Display
Color display 1,44", 128 x 128 pixels
2 x LED, yellow
Remarks
MW = Measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Reliable detection of flow and medium temperature
With switching output or frequency output and IO-Link
Display can be rotated for optimum alignment
Clearly readable color display with red/green color change
Suitable for water, deionized water and cooling water
Convenient operation via buttons or parameter setting via IO-Link