| Number of inputs and outputs |
Number of analog outputs: 2 |
| Measuring range |
| 2...40 l/min | 0.12...2.4 m³/h |
|
| Process connection |
threaded connection Rc 1/2 Internal thread DN10 |
| System |
gold-plated contacts |
| Application |
for industrial applications |
| Media |
water; glycol solutions; Coolants |
| Medium temperature |
-10...90 |
| Pressure rating |
|
| Note on pressure rating |
|
| Operating voltage |
18...30 DC |
| Current consumption |
< 30 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
< 3 |
| Measuring principle |
Vortex |
| Number of inputs and outputs |
Number of analog outputs: 2 |
| Total number of outputs |
2 |
| Output signal |
analog signal |
| Number of analog outputs |
2 |
| Analog current output |
4...20 |
| Max. load |
500 |
| Short-circuit protection |
yes |
| Overload protection |
yes |
| Measuring range |
| 2...40 l/min | 0.12...2.4 m³/h |
|
| Display range |
| 0...48 l/min | 0...2.88 m³/h |
|
| Resolution |
|
| Analog start point ASP |
| 0...32 l/min | 0...1.92 m³/h |
|
| Analog end point AEP |
| 8...40 l/min | 0.48...2.4 m³/h |
|
| In steps of |
|
| Measuring dynamics |
1:20 |
| Dynamic response T05 / T09 |
T09 = 6 |
| Response time |
1; (dAP = 0) |
| Damping process value dAP |
0...5 |
| Parameter setting options |
Damping for the analog output dAA; Display unit |
| Ambient temperature |
0...60 |
| Note on ambient temperature |
| medium temperature < 80 °C | | medium temperature < 90 °C: 0...50 °C |
|
| Storage temperature |
-20...80 |
| Protection |
IP 65; IP 67 |
| EMC |
| DIN EN 61000-6-2 | | | DIN EN 61000-6-3 | |
|
| CPA approval |
| model number | 001VO | | accuracy class | - | | maximum allowable error | ± 2 % FS | | Q (min) | 0,15 m³/h | | Q (t) | 0,48 m³/h | | Q (max) | 2,4 m³/h |
|
| Shock resistance |
| DIN EN 60068-2-27 | 5 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm | | with water / 50...2000 Hz 2 g |
|
| MTTF |
342 |
| UL approval |
|
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight |
440.5 |
| Housing |
rectangular |
| Dimensions |
110 x 45 x 72 |
| Material |
stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
| Tightening torque |
30 |
| Process connection |
threaded connection Rc 1/2 Internal thread DN10 |
| Display |
| Color display 1,44", 128 x 128 pixels | | 2 x LED, yellow |
|
| Remarks |
| MW = Measured value | | MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |