Характеристики

Output function normally open / closed; (configurable)
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Measuring range temperature -10...90 °C
Measuring range 0.12...2.4
Process connection Rc 1/2 Internal thread DN10

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range <table><tr><td>2...40 l/min</td><td>0.12...2.4 m³/h</td></tr></table>
Process connection threaded connection Rc 1/2 Internal thread DN10
Application
System gold-plated contacts
Application for industrial applications
Media water; glycol solutions; Coolants
Medium temperature -10...90
Pressure rating <table><tr><td>12 bar</td><td>1.2 MPa</td></tr></table>
Note on pressure rating <table><tr><td>up to 40 °C </td></tr></table>
Electrical data
Operating voltage 18...30 DC
Current consumption < 30
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time < 3
Measuring principle Vortex
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 100
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>2...40 l/min</td><td>0.12...2.4 m³/h</td></tr></table>
Display range <table><tr><td>0...48 l/min</td><td>0...2.88 m³/h</td></tr></table>
Resolution <table><tr><td>0.2 l/min</td><td>0.01 m³/h</td></tr></table>
Set point SP <table><tr><td>2.4...40 l/min</td><td>0.14...2.4 m³/h</td></tr></table>
Reset point rP <table><tr><td>2...39.6 l/min</td><td>0.12...2.38 m³/h</td></tr></table>
Frequency end point, FEP <table><tr><td>8...40 l/min</td><td>0.48...2.4 m³/h</td></tr></table>
In steps of <table><tr><td>0.2 l/min</td><td>0.01 m³/h</td></tr></table>
Frequency at the end point FRP 100...1000
Measuring dynamics 1:20
Temperature monitoring
Dynamic response T05 / T09 T09 = 6
Accuracy / deviations
Flow monitoring
Response time 1; (dAP = 0)
Damping process value dAP 0...5
Reaction times
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 3
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>488</td></tr></table>
Operating conditions
Ambient temperature 0...60
Note on ambient temperature <table><tr><td>medium temperature < 80 °C </td></tr><tr><td>medium temperature < 90 °C: 0...50 °C</td></tr></table>
Storage temperature -20...80
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
CPA approval <table><tr><td>model number</td><td>001VO</td></tr><tr><td>accuracy class</td><td>-</td></tr><tr><td>maximum allowable error</td><td>± 2 % FS</td></tr><tr><td>Q (min)</td><td>0,15 m³/h</td></tr><tr><td>Q (t)</td><td>0,48 m³/h</td></tr><tr><td>Q (max)</td>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>5 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>with water / 10...50 Hz 1 mm</td></tr><tr><td></td><td>with water / 50...2000 Hz 2 g</td></tr></table>
MTTF 342
UL approval <table><tr><td>UL approval number</td><td>I001 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 441
Housing rectangular
Dimensions 110 x 45 x 72
Material stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts) stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque 30
Process connection threaded connection Rc 1/2 Internal thread DN10
Displays / operating elements
Display <table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td></td><td>2 x LED, yellow</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr></table>
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Reliable detection of flow and medium temperature
With switching output or frequency output and IO-Link
Display can be rotated for optimum alignment
Clearly readable color display with red/green color change
Suitable for water, deionized water and cooling water
Convenient operation via buttons or parameter setting via IO-Link