| Product characteristics |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
<table><tr><td>16...317 gph</td><td>0.26...5.28 gpm</td></tr></table> |
| Process connection |
threaded connection 1/2" NPT Internal thread DN8 |
| Application |
|
| System |
gold-plated contacts |
| Application |
for industrial applications |
| Media |
water; glycol solutions; Coolants |
| Medium temperature |
14...194 |
| Pressure rating |
<table><tr><td>12 bar</td><td>174 psi</td><td>1.2 MPa</td></tr></table> |
| Note on pressure rating |
<table><tr><td>up to 40 °C </td></tr></table> |
| MAWP (for applications according to CRN) |
3.9 |
| Electrical data |
|
| Operating voltage |
18...30 DC |
| Current consumption |
< 30 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
< 3 |
| Measuring principle |
Vortex |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
switching signal; frequency signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2.5 |
| Permanent current rating of switching output DC |
100 |
| Short-circuit protection |
yes |
| Overload protection |
yes |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>16...317 gph</td><td>0.26...5.28 gpm</td></tr></table> |
| Display range |
<table><tr><td>0...380 gph</td><td>0...6.34 gpm</td></tr></table> |
| Resolution |
<table><tr><td>1 gph</td><td>0.02 gpm</td></tr></table> |
| Set point SP |
<table><tr><td>19...317 gph</td><td>0.32...5.28 gpm</td></tr></table> |
| Reset point rP |
<table><tr><td>16...314 gph</td><td>0.26...5.24 gpm</td></tr></table> |
| Frequency end point, FEP |
<table><tr><td>63...317 gph</td><td>1.06...5.28 gpm</td></tr></table> |
| In steps of |
<table><tr><td>1 gph</td><td>0.02 gpm</td></tr></table> |
| Frequency at the end point FRP |
100...1000 |
| Measuring dynamics |
1:20 |
| Temperature monitoring |
|
| Dynamic response T05 / T09 |
T09 = 6 |
| Accuracy / deviations |
|
| Flow monitoring |
|
| Response time |
1; (dAP = 0) |
| Damping process value dAP |
0...5 |
| Reaction times |
|
| Software / programming |
|
| Parameter setting options |
hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
<table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table> |
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
2 |
| Process data binary |
2 |
| Min. process cycle time |
3 |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>486</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
32...140 |
| Note on ambient temperature |
<table><tr><td>medium temperature < 176 °F </td></tr><tr><td>medium temperature < 194 °F: 32...122 °F</td></tr></table> |
| Storage temperature |
-4...176 |
| Protection |
IP 65; IP 67 |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table> |
| Shock resistance |
<table><tr><td>DIN EN 60068-2-27</td><td>5 g (11 ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN EN 60068-2-6</td><td>with water / 10...50 Hz 1 mm</td></tr><tr><td></td><td>with water / 50...2000 Hz 2 g</td></tr></table> |
| MTTF |
342 |
| UL approval |
<table><tr><td>UL approval number</td><td>I001 </td></tr></table> |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical data |
|
| Weight |
481.5 |
| Housing |
rectangular |
| Dimensions |
119 x 45 x 72 |
| Material |
stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
| Tightening torque |
30 |
| Process connection |
threaded connection 1/2" NPT Internal thread DN8 |
| Displays / operating elements |
|
| Display |
<table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td></td><td>2 x LED, yellow</td></tr></table> |
| Remarks |
|
| Remarks |
<table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr></table> |
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |