Характеристики

Materials (wetted parts) Pipe section: stainless steel (1.4435 / 316L); Process connection: stainless steel (1.4404 / 316L)
Measuring range 1.5...216
Electrical design PNP/NPN
Process connection Clamp DN80

Все характеристики

Product characteristics
Measuring range <table><tr><td>25...3600 l/min</td><td>1.5...216 m³/h</td><td>400...57061 gph</td><td>6.6...951 gpm</td></tr></table>
Nominal diameter DN80 (3“)
Process connection Clamp DN80 DIN 32676 series A
Application
System gold-plated contacts
Application food and beverage industry
Media ultra-pure water; water; water-based media
Note on media <table><tr><td>water-based media: for media with >10 % additives, the repeatability is the only available value</td></tr></table>
Medium temperature -40...120; (< 1 h: 150)
Min. bursting pressure <table><tr><td>40 bar</td><td>4 MPa</td></tr></table>
Pressure rating <table><tr><td>16 bar</td><td>1.6 MPa</td></tr></table>
Vacuum resistance -1000
Electrical data
Operating voltage 18...32 DC; (to SELV/PELV)
Current consumption < 75
Protection class III
Reverse polarity protection yes
Power-on delay time 5
Measuring principle ultrasonic
Inputs / outputs
Total number of inputs and outputs 2
Inputs
Inputs <table><tr><td>OUT2</td><td>counter reset</td></tr></table>
Outputs
Total number of outputs 2
Output signal <table><tr><td>OUT1</td><td>switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link</td></tr><tr><td>OUT2</td><td>switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal
Electrical design PNP/NPN
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Analog
Number of analog outputs 1
Analog current output 4...20
Max. load 500
Digital
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 100
Switching frequency DC 0...10000
Measuring/setting range
Measuring range <table><tr><td>25...3600 l/min</td><td>1.5...216 m³/h</td><td>400...57061 gph</td><td>6.6...951 gpm</td></tr></table>
Resolution <table><tr><td>0.1 l/min</td><td>0.001 m³/h</td><td>1 gph</td><td>0.01 gpm</td></tr></table>
Note on factory setting <table><tr><td> l/min, °C</td></tr><tr><td></td></tr></table>
Set point SP <table><tr><td>44.8...3600 l/min</td><td>2.7...216 m³/h</td><td>710...57061 gph</td><td>11.8...951 gpm</td></tr></table>
Reset point rP <table><tr><td>26.1...3581.3 l/min</td><td>1.6...214.9 m³/h</td><td>413...56764 gph</td><td>6.9...946.1 gpm</td></tr></table>
Analog start point ASP <table><tr><td>-3600...2880 l/min</td><td>-216...172.8 m³/h</td><td>-57060...45650 gph</td><td>-951...760.8 gpm</td></tr></table>
Analog end point AEP <table><tr><td>-2880...3600 l/min</td><td>-172.8...216 m³/h</td><td>-45650...57060 gph</td><td>-760.8...951 gpm</td></tr></table>
Low flow cut-off LFC <table><tr><td>25...180 l/min</td><td>1.5...10.8 m³/h</td><td>400...2850 gph</td><td>6.6...47.6 gpm</td></tr></table>
Frequency end point, FEP <table><tr><td>722.2...3600 l/min</td><td>43.3...216 m³/h</td><td>11450...57060 gph</td><td>190.8...951 gpm</td></tr></table>
Frequency at the end point FRP 1...10000
Volumetric flow quantity monitoring
Pulse length 0.002...2
Pulse value 0.1...99990000 I; 0.026…26414563.515 gal
Temperature monitoring
Dynamic response T05 / T09 5,7 / 86
Accuracy / deviations
Accuracy (in the measuring range) only up to 100 °C; at higher temperatures, only the repeatability is within the specification.
Flow monitoring
Response time < 0.5; (dAP = 0, T09)
Damping process value dAP 0...5
Reaction times
Software / programming
Diagnostic functions direction of flow detection; signal quality
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9: 2013-07
Profiles <table><tr><td>BLOB</td><td>Binary Large Object transfer</td></tr><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr></table>
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time 9.6
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>totalizer</td><td>32</td></tr><tr><td>Flow monitoring</td><td>32</td></tr><tr><td>Temperature monitoring</td><td>32</td></tr><tr><td>status</td><td>4</td></tr><tr><td>Output 1</td><td>1</td></tr>
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1856</td></tr></table>
Operating conditions
Ambient temperature -20...60
Storage temperature -25...80
Protection IP 69; (DIN EN 60529)
Tests / approvals
EMC <table><tr><td>DIN 61326-1:2021</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>20 g (11ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6</td><td>20 g (10...2000Hz)</td></tr></table>
MTTF 136
UL approval <table><tr><td>UL approval number</td><td>I039 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 1975.15
Housing rectangular
Inlet pipe length 15 x DN
Outlet pipe length 3 x DN
Dimensions 220 x 106 x 152.9
Material housing: stainless steel (1.4404 / 316L); connector: PEI, FKM
Materials (wetted parts) Pipe section: stainless steel (1.4435 / 316L); Process connection: stainless steel (1.4404 / 316L)
Nominal diameter DN80 (3“)
Process connection Clamp DN80 DIN 32676 series A
Process connection suitable for pipe standard DN80 / Ø 85 mm x 2 mm; (DIN 11866 series A); (DIN EN 10357 series A)
Surface characteristics Ra/Rz of the wetted parts Ra < 0.4 µm (16 µin); Rz = 4 µm (157 µin)
Displays / operating elements
Display <table><tr><td>operating status</td><td>1 x LED, green</td></tr></table>
Accessories
Items supplied <table><tr><td>package insert</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> pulse and totalizer signal are only available for one of the two outputs</td></tr><tr><td> the specified surface characteristics Ra/Rz of the we
Pack quantity 1 pcs.
Electrical connection - plug
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance
The highly accurate inline measurement process eliminates any influence of varying wall thicknesses and pipe materials
Operating status LED signals the sensor status and allows conclusions about process quality
User-friendly communication and parameterization via IO-Link