| Product characteristics |
|
| Measuring range |
<table><tr><td>5...1000 l/min</td><td>300...60000 l/h</td><td>0.058...11.666 m/s</td><td>0.3...60 m³/h</td></tr></table> |
| Nominal diameter |
DN50 (2“) |
| Process connection |
Clamp 2" DIN 32676 series C (ASME BPE) |
| Application |
|
| System |
gold-plated contacts |
| Media |
ultra-pure water; water; water-based media; edible oils |
| Note on media |
<table><tr><td>water-based media: for media with >10 % additives, the repeatability is the only available value</td></tr><tr><td> edible oils: palm oil, soy oil, rapeseed oil, sunflower oil, peanut oil, olive oil and others</td></tr></table> |
| Medium temperature |
-20...100 |
| Min. bursting pressure |
<table><tr><td>50 bar</td><td>5 MPa</td></tr></table> |
| Pressure rating |
<table><tr><td>16 bar</td><td>1.6 MPa</td></tr></table> |
| Vacuum resistance |
-1000 |
| Electrical data |
|
| Operating voltage |
18...32 DC; (to SELV/PELV) |
| Current consumption |
< 75 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
5 |
| Measuring principle |
ultrasonic |
| Inputs / outputs |
|
| Total number of inputs and outputs |
2 |
| Inputs |
|
| Inputs |
<table><tr><td>OUT2</td><td>counter reset</td></tr></table> |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
<table><tr><td>OUT1</td><td>switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link</td></tr><tr><td>OUT2</td><td>switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal |
| Electrical design |
PNP/NPN |
| Min. load resistance |
2000 |
| Pulse output |
flow rate meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Analog |
|
| Number of analog outputs |
1 |
| Analog current output |
4...20 |
| Max. load |
500 |
| Digital |
|
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
100 |
| Switching frequency DC |
0...10000 |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>5...1000 l/min</td><td>300...60000 l/h</td><td>0.058...11.666 m/s</td><td>0.3...60 m³/h</td></tr></table> |
| Display range |
<table><tr><td>-1200...1200 l/min</td><td>-72000...72000 l/h</td><td>-13.999...13.999 m/s</td><td>-72...72 m³/h</td></tr></table> |
| Resolution |
<table><tr><td>0.1 l/min</td><td>1 l/h</td><td>0.001 m/s</td><td>0.002 m³/h</td></tr></table> |
| Set point SP |
<table><tr><td>10.5...1000 l/min</td><td>630...60000 l/h</td><td>0.122...11.666 m/s</td><td>0.63...60 m³/h</td></tr></table> |
| Reset point rP |
<table><tr><td>5.3...994.8 l/min</td><td>318...59688 l/h</td><td>0.062...11.605 m/s</td><td>0.318...59.688 m³/h</td></tr></table> |
| Analog start point ASP |
<table><tr><td>-1000...800 l/min</td><td>-60000...48000 l/h</td><td>-11.666...9.333 m/s</td><td>-60...48 m³/h</td></tr></table> |
| Analog end point AEP |
<table><tr><td>-800...1000 l/min</td><td>-48000...60000 l/h</td><td>-9.333...11.666 m/s</td><td>-48...60 m³/h</td></tr></table> |
| Low flow cut-off LFC |
<table><tr><td>5...50 l/min</td><td>300...3000 l/h</td><td>0.058...0.583 m/s</td><td>0.3...3 m³/h</td></tr></table> |
| Frequency end point, FEP |
<table><tr><td>200.6...1000 l/min</td><td>12037...60000 l/h</td><td>2.34...11.666 m/s</td><td>12.037...60 m³/h</td></tr></table> |
| Frequency at the end point FRP |
1...10000 |
| Volumetric flow quantity monitoring |
|
| Pulse length |
0.002...2 |
| Pulse value |
0.1...99990000 I |
| Temperature monitoring |
|
| Dynamic response T05 / T09 |
5,7 / 86 |
| Accuracy / deviations |
|
| Flow monitoring |
|
| Response time |
< 0.25; (dAP = 0, T09) |
| Damping process value dAP |
0...5 |
| Reaction times |
|
| Software / programming |
|
| Diagnostic functions |
direction of flow detection; signal quality |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1.3 |
| SDCI standard |
IEC 61131-9: 2013-07 |
| Profiles |
<table><tr><td>BLOB</td><td>Binary Large Object transfer</td></tr><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr></table> |
| Required master port class |
A |
| Process data analog |
3 |
| Process data binary |
2 |
| Min. process cycle time |
9.6 |
| IO-Link process data (cyclical) |
<table><tr><th>Function</th><th>bit length</th></tr><tr><td>totalizer</td><td>32</td></tr><tr><td>Flow monitoring</td><td>32</td></tr><tr><td>Temperature monitoring</td><td>32</td></tr><tr><td>status</td><td>4</td></tr><tr><td>Output 1</td><td>1</td></tr> |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1752</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
-20...60 |
| Storage temperature |
-25...80 |
| Protection |
IP 69K |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN 61326-1:2021</td><td></td></tr></table> |
| CPA approval |
<table><tr><td>model number</td><td>003US</td></tr><tr><td>accuracy class</td><td>1,5</td></tr></table> |
| Shock resistance |
<table><tr><td>DIN IEC 68-2-27</td><td>20 g (11ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN IEC 68-2-6</td><td>20 g (10...2000Hz)</td></tr></table> |
| MTTF |
160 |
| UL approval |
<table><tr><td>UL approval number</td><td>I033 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table> |
| Pressure equipment directive |
can be used for group 2 fluids; group 1 fluids on request |
| Mechanical data |
|
| Weight |
933 |
| Housing |
rectangular |
| Inlet pipe length |
5 x DN |
| Outlet pipe length |
1 x DN |
| Dimensions |
220 x 63.9 x 92.6 |
| Material |
housing: stainless steel (1.4404 / 316L); Display: PFA; sealing Display: FKM; connector: PBT |
| Materials (wetted parts) |
Pipe section: stainless steel (1.4404 / 316L) |
| Nominal diameter |
DN50 (2“) |
| Process connection |
Clamp 2" DIN 32676 series C (ASME BPE) |
| Process connection suitable for pipe standard |
2" / Ø 50,8 mm x 1,65 mm (DIN 11866 series C); (DIN EN 10357 Series D) |
| Surface characteristics Ra/Rz of the wetted parts |
Ra < 0.4 μm; Rz = 4 μm |
| Displays / operating elements |
|
| Display |
<table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td>Switching function</td><td>2 x LED, yellow</td></tr><tr><td>diagnosis</td><td>1 x LED, three-color</td></tr></table> |
| Remarks |
|
| Remarks |
<table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> pulse and totalizer signal are only available for one of the two outputs</td></tr><tr><td> the accuracy indications are adhered to over the enti |
| Pack quantity |
1 pcs. |
| Electrical connection |
|