Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

SMF920 – фото
SMF920 – фото
SMF920 – фото
Фото
Видео

На SMF920

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Measuring range 6...600
Materials (wetted parts) Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L)
Electrical design PNP/NPN
Process connection ifm-specific device flange

Все характеристики

Product characteristics
Measuring range <table><tr><td>100...10000 l/min</td><td>6000...600000 l/h</td><td>0.09...9.43 m/s</td><td>6...600 m³/h</td></tr></table>
Nominal diameter DN150 (6“)
Process connection ifm-specific device flange
Application
System gold-plated contacts
Application food and beverage industry
Media Conductive liquids; water; water-based media
Note on media <table><tr><td> food products such as beer, milk, fruit juices, soft drinks, ketchup, yogurt, yogurt toppings, ice cream</td></tr><tr><td>conductivity: ≥ 5 µS/cm</td></tr></table>
Medium temperature -20...150
Min. bursting pressure <table><tr><td>37.5 bar</td><td>3.75 MPa</td></tr></table>
Pressure rating <table><tr><td>25 bar</td><td>2.5 MPa</td></tr></table>
Electrical data
Operating voltage 18...32 DC
Current consumption 250; (24V)
Protection class III
Reverse polarity protection yes
Power-on delay time < 5
Measuring principle magnetic-inductive
Inputs / outputs
Total number of inputs and outputs 2
Inputs
Inputs <table><tr><td>OUT2</td><td>external totalizer reset</td></tr></table>
Outputs
Total number of outputs 2
Output signal <table><tr><td>OUT1</td><td>pulse signal; totalizer switching signal; diagnostic signal; IO-Link</td></tr><tr><td>OUT2</td><td>analog signal; pulse signal; totalizer switching signal; diagnostic signal</td></tr></table>
Electrical design PNP/NPN
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Analog
Number of analog outputs 1
Analog current output 4...20; (skalierbar)
Max. load 500
Resolution of analog output 0.38 µA
Digital
Number of digital outputs 2
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 100
Switching frequency DC 0...10000
Measuring/setting range
Measuring range <table><tr><td>100...10000 l/min</td><td>6000...600000 l/h</td><td>0.09...9.43 m/s</td><td>6...600 m³/h</td></tr></table>
Display range <table><tr><td>-12000...12000 l/min</td><td>-720000...720000 l/h</td><td>-11.32...11.32 m/s</td><td>-720...720 m³/h</td></tr></table>
Resolution <table><tr><td>0.1 l/min</td><td>100 l/h</td><td>0.01 m/s</td><td>0.1 m³/h</td></tr></table>
Note on factory setting <table><tr><td>0...160,0 m³/h </td></tr></table>
Analog start point ASP <table><tr><td>-10000...8000 l/min</td><td>-600000...480000 l/h</td><td>-9.43...7.55 m/s</td><td>-600...480 m³/h</td></tr></table>
Analog end point AEP <table><tr><td>-8000...10000 l/min</td><td>-480000...600000 l/h</td><td>-7.55...9.43 m/s</td><td>-480...600 m³/h</td></tr></table>
Low flow cut-off LFC <table><tr><td>0...8000 l/min</td><td>0...480000 l/h</td><td>0...7.43 m/s</td><td>0...480 m³/h</td></tr></table>
Pulse length 0.00005...2
Pulse value 0.017...99999000 I
Temperature monitoring
Response time < 3; (Flow velocity: ≥ 0,5m/s)
Conductivity monitoring
Response time < 2
Accuracy / deviations
Volumetric flow monitoring
Response time < 0.3
Damping process value dAP 0...5
Reaction times
Software / programming
Diagnostic functions direction of flow detection; liquid detection
Interfaces
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9
Profiles <table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Smart Sensor - SSP 4.3.4</td><td>Measuring and Switching Sensor, floating point, 4 channel</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 6
Process data binary 8
Min. process cycle time 1.9
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>totalizer</td><td>32</td></tr><tr><td>flow</td><td>32</td></tr><tr><td>temperature</td><td>32</td></tr><tr><td>conductivity</td><td>32</td></tr><tr><td>status</td><td>4</td></tr><tr><td>binary sw
IO-Link functions (acyclical) direction of flow detection; totalizer; memory; operating hours counter; internal temperature; simulation function
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1807</td></tr></table>
Operating conditions
Ambient temperature -20...65
Storage temperature -20...80
Protection IP 67; IP 69; (to DIN EN 60529)
Tests / approvals
EMC <table><tr><td>DIN 61326-1</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>20 g (18ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6</td><td>5 g (10...2000Hz)</td></tr></table>
MTTF 81
UL approval <table><tr><td>UL approval number</td><td>I031 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 17264
Housing tubular
Inlet pipe length 5 x DN
Outlet pipe length 2 x DN
Dimensions Ø 255 / L = 200
Material housing: stainless steel (1.4404 / 316L); flange: stainless steel (1.4301 / 304); electronics fixture: stainless steel (1.4301 / 304); electronics: stainless steel (1.4404 / 316L); Display: polysulfone; Display-sealing: FKM; LED ring: PP
Materials (wetted parts) Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L)
Nominal diameter DN150 (6“)
Process connection ifm-specific device flange
Surface characteristics Ra/Rz of the wetted parts Ra < 0.4 μm
Displays / operating elements
Display <table><tr><td>process value</td><td>full graphics TFT display, multi-color 3,5" 320 x 240 Pixel</td></tr><tr><td></td><td>display layouts: 4</td></tr><tr><td></td><td>display rotation: 4 x 90°</td></tr><tr><td>operating status</td><td>LED ring, three-col
Display unit l/min; l/h; hl/min; hl/h; m³/min; m³/h; m/s; °C; μS/cm; S/m; ms/cm
Factory setting m³/h; °C; μS/cm
Language German; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese
Operating elements <table><tr><td>4</td><td>capacitive pushbuttons</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> pulse and totalizer signal are only available for one of the two outputs</td></tr><tr><td>reference conditions (1/2): water (free of gas bubble
Pack quantity 1 pcs.
Electrical connection - plug
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Magnetic-inductive flow meter (SM Foodmag series) for the food and beverage industry
Measured variables: flow rate, total volume, temperature, conductivity and fluid detection
Easy to set up thanks to app-based menu, guided installation and hygienic pushbuttons
Reduced cabling by combining supply voltage and output signals via an M12 connection
Housing design increases shock and vibration resistance
User-friendly communication and parameterization via IO-Link