| Product characteristics |
|
| Measuring range |
<table><tr><td>20...2000 l/min</td><td>1200...120000 l/h</td><td>5.5...528.5 gpm</td><td>0.32...32.96 ft/s</td></tr></table> |
| Nominal diameter |
DN65 (2 1/2“) |
| Process connection |
ifm-specific device flange |
| Application |
|
| System |
gold-plated contacts |
| Application |
food and beverage industry |
| Media |
Conductive liquids; water; water-based media |
| Note on media |
<table><tr><td> food products such as beer, milk, fruit juices, soft drinks, ketchup, yogurt, yogurt toppings, ice cream</td></tr><tr><td>conductivity: ≥ 5 µS/cm</td></tr></table> |
| Medium temperature |
<table><tr><td>-20...150 °C</td><td>-4...302 °F</td></tr></table> |
| Min. bursting pressure |
<table><tr><td>543.75 psi</td><td>3.75 MPa</td></tr></table> |
| Pressure rating |
<table><tr><td>362.5 psi</td><td>2.5 MPa</td></tr></table> |
| Electrical data |
|
| Operating voltage |
18...32 DC |
| Current consumption |
250; (24V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
< 5 |
| Measuring principle |
magnetic-inductive |
| Inputs / outputs |
|
| Total number of inputs and outputs |
2 |
| Inputs |
|
| Inputs |
<table><tr><td>OUT2</td><td>external totalizer reset</td></tr></table> |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
<table><tr><td>OUT1</td><td>pulse signal; totalizer switching signal; diagnostic signal; IO-Link</td></tr><tr><td>OUT2</td><td>analog signal; pulse signal; totalizer switching signal; diagnostic signal</td></tr></table> |
| Electrical design |
PNP/NPN |
| Pulse output |
flow rate meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Analog |
|
| Number of analog outputs |
1 |
| Analog current output |
4...20; (skalierbar) |
| Max. load |
500 |
| Resolution of analog output |
0.38 µA |
| Digital |
|
| Number of digital outputs |
2 |
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
100 |
| Switching frequency DC |
0...10000 |
| Measuring/setting range |
|
| Measuring range |
<table><tr><td>20...2000 l/min</td><td>1200...120000 l/h</td><td>5.5...528.5 gpm</td><td>0.32...32.96 ft/s</td></tr></table> |
| Display range |
<table><tr><td>-2400...2400 l/min</td><td>-144000...144000 l/h</td><td>-634.01...634.01 gpm</td><td>-39.4...39.4 ft/s</td></tr></table> |
| Resolution |
<table><tr><td>0.1 l/min</td><td>100 l/h</td><td>0.01 gpm</td><td>0.01 ft/s</td></tr></table> |
| Note on factory setting |
<table><tr><td>0…130 gpm </td></tr></table> |
| Analog start point ASP |
<table><tr><td>-2000...1600 l/min</td><td>-120000...96000 l/h</td><td>-528.4...422.72 gpm</td><td>-32.8...26.24 ft/s</td></tr></table> |
| Analog end point AEP |
<table><tr><td>-1600...2000 l/min</td><td>-96000...120000 l/h</td><td>-422.72...528.4 gpm</td><td>-26.24...32.8 ft/s</td></tr></table> |
| Low flow cut-off LFC |
<table><tr><td>0...1600 l/min</td><td>0...96000 l/h</td><td>0...422.72 gpm</td><td>0...26.24 ft/s</td></tr></table> |
| Pulse length |
0.00005...2 |
| Pulse value |
0.004...99990000 I |
| Temperature monitoring |
|
| Response time |
< 3; (Flow velocity: ≥ 0,5m/s) |
| Conductivity monitoring |
|
| Response time |
< 2 |
| Accuracy / deviations |
|
| Volumetric flow monitoring |
|
| Response time |
< 0.3 |
| Damping process value dAP |
0...5 |
| Reaction times |
|
| Software / programming |
|
| Diagnostic functions |
direction of flow detection; liquid detection |
| Interfaces |
|
| Communication interface |
IO-Link |
| Transmission type |
COM3 (230,4 kBaud) |
| IO-Link revision |
1.1.3 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
<table><tr><td>Smart Sensor - SSP 4.3.4</td><td>Measuring and Switching Sensor, floating point, 4 channel</td></tr><tr><td>BLOB</td><td>Binary Large Object transfer</td></tr><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Extens |
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
6 |
| Process data binary |
8 |
| Min. process cycle time |
1.9 |
| IO-Link process data (cyclical) |
<table><tr><th>Function</th><th>bit length</th></tr><tr><td>totalizer</td><td>32</td></tr><tr><td>flow</td><td>32</td></tr><tr><td>temperature</td><td>32</td></tr><tr><td>conductivity</td><td>32</td></tr><tr><td>status</td><td>4</td></tr><tr><td>binary sw |
| IO-Link functions (acyclical) |
direction of flow detection; totalizer; memory; operating hours counter; internal temperature; simulation function |
| Supported DeviceIDs |
<table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1796</td></tr></table> |
| Operating conditions |
|
| Ambient temperature |
<table><tr><td>-20...65 °C</td><td>-4...149 °F</td></tr></table> |
| Storage temperature |
<table><tr><td>-20...80 °C</td><td>-4...176 °F</td></tr></table> |
| Protection |
IP 67; IP 69; (to DIN EN 60529) |
| Tests / approvals |
|
| EMC |
<table><tr><td>DIN 61326-1</td><td></td></tr></table> |
| CPA approval |
<table><tr><td>model number</td><td>SMF</td></tr><tr><td>accuracy class</td><td>0,5</td></tr></table> |
| Shock resistance |
<table><tr><td>DIN IEC 68-2-27</td><td>20 g (18ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN IEC 68-2-6</td><td>5 g (10...2000Hz)</td></tr></table> |
| MTTF |
81 |
| UL approval |
<table><tr><td>UL approval number</td><td>I031 </td></tr></table> |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical data |
|
| Weight |
6897 |
| Inlet pipe length |
5 x DN |
| Outlet pipe length |
2 x DN |
| Material |
housing: stainless steel (1.4404 / 316L); flange: stainless steel (1.4301 / 304); electronics fixture: stainless steel (1.4301 / 304); electronics: stainless steel (1.4404 / 316L); Display: polysulfone; Display-sealing: FKM; LED ring: PP |
| Materials (wetted parts) |
Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L) |
| Nominal diameter |
DN65 (2 1/2“) |
| Process connection |
ifm-specific device flange |
| Surface characteristics Ra/Rz of the wetted parts |
Ra < 0.4 μm |
| Displays / operating elements |
|
| Display |
<table><tr><td>process value</td><td>full graphics TFT display, multi-color 3,5" 320 x 240 Pixel</td></tr><tr><td></td><td>display layouts: 4</td></tr><tr><td></td><td>display rotation: 4 x 90°</td></tr><tr><td>operating status</td><td>LED ring, three-col |
| Display unit |
l/min; l/h; hl/min; hl/h; m³/min; m³/h; m/s; gpm; gph; ft/s; °C; °F; μS/cm; S/m; ms/cm |
| Factory setting |
gpm; °F; μS/cm |
| Language |
German; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese |
| Operating elements |
<table><tr><td>4</td><td>capacitive pushbuttons</td></tr></table> |
| Remarks |
|
| Remarks |
<table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> pulse and totalizer signal are only available for one of the two outputs</td></tr><tr><td>reference conditions (1/2): water (free of gas bubble |
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |