Характеристики

Output function normally open / closed; (configurable); analog
Materials (wetted parts) Pipe section: stainless steel (1.4404 / 316L); Process connection sealing: NBR fiber-reinforced Gasket; FKM; PEEK; carbon fiber PEEK
Measuring range 0.012...9
Electrical design PNP/NPN
Process connection G 1 external thread DN25

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>0.2...150 l/min</td><td>0.012...9 m³/h</td><td>3.6...2376 gph</td><td>0.06...39.6 gpm</td></tr></table>
Process connection threaded connection G 1 external thread DN25 flat seal
Application
System gold-plated contacts
Media Conductive liquids; water; water-based media
Note on media <table><tr><td>conductivity: ≥ 20 µS/cm</td></tr><tr><td>viscosity: < 70 mm²/s (40 °C)</td></tr></table>
Medium temperature -20...90
Pressure rating <table><tr><td>16 bar</td><td>1.6 MPa</td></tr></table>
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 80
Protection class III
Reverse polarity protection yes
Power-on delay time 5
Measuring principle magnetic-inductive
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputs counter reset
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; pulse signal; IO-Link; frequency signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 100
Number of analog outputs 1
Analog current output 4...20; (scalable)
Max. load 500
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>0.2...150 l/min</td><td>0.012...9 m³/h</td><td>3.6...2376 gph</td><td>0.06...39.6 gpm</td></tr></table>
Display range <table><tr><td>-180...180 l/min</td><td>-10.8...10.8 m³/h</td><td>-2853.6...2853.6 gph</td><td>-47.56...47.56 gpm</td></tr></table>
Resolution <table><tr><td>0.1 l/min</td><td>0.006 m³/h</td><td>0.6 gph</td><td>0.01 gpm</td></tr></table>
Set point SP <table><tr><td>1...150 l/min</td><td>0.06...9 m³/h</td><td>16.2...2376 gph</td><td>0.27...39.6 gpm</td></tr></table>
Reset point rP <table><tr><td>0.2...149.2 l/min</td><td>0.012...8.95 m³/h</td><td>3.6...1903 gph</td><td>0.06...39.42 gpm</td></tr></table>
Analog start point ASP <table><tr><td>0...120 l/min</td><td>0...7.2 m³/h</td><td>0...1903 gph</td><td>0...31.71 gpm</td></tr></table>
Analog end point AEP <table><tr><td>30...150 l/min</td><td>1.8...9 m³/h</td><td>475...2376 gph</td><td>7.92...39.6 gpm</td></tr></table>
Low flow cut-off LFC <table><tr><td>0.2...7.5 l/min</td><td>0.012...0.45 m³/h</td><td>3...118.4 gph</td><td>0.05...1.98 gpm</td></tr></table>
Frequency end point, FEP <table><tr><td>30.2...150 l/min</td><td>1.8...9 m³/h</td><td>480...2376 gph</td><td>8...39.6 gpm</td></tr></table>
Frequency at the end point FRP 1...10000
Volumetric flow quantity monitoring
Pulse length 0.002...2
Pulse value 0.01...99990000 I
Temperature monitoring
Response time 15; (Q > 10 % MEW, T09)
Accuracy / deviations
Flow monitoring
Start-up delay 0...50
Response time < 0.25; (dAP = 0, T09)
Damping process value dAP 0...5
Reaction times
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; Frequency output; current/pulse output; Start-up delay; display can be deactivated; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Measurement data, standard resolution</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time 8
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>961</td></tr></table>
Operating conditions
Ambient temperature -20...60
Storage temperature -25...80
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 60947-5-9</td><td></td></tr></table>
CPA approval <table><tr><td>model number</td><td>006MI</td></tr><tr><td>accuracy class</td><td>-</td></tr><tr><td>maximum allowable error</td><td>± 1,0 % FS</td></tr><tr><td>Q (min)</td><td>0,01 m³/h</td></tr><tr><td>Q (t)</td><td>-</td></tr><tr><td>Q (max)</td><td>9
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>20 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6:</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 114
UL approval <table><tr><td>UL approval number</td><td>I014 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 782
Housing rectangular
Dimensions 110 x 48 x 73
Material stainless steel (1.4408/316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30
Materials (wetted parts) Pipe section: stainless steel (1.4404 / 316L); Process connection sealing: NBR fiber-reinforced Gasket; FKM; PEEK; carbon fiber PEEK
Process connection threaded connection G 1 external thread DN25 flat seal
Displays / operating elements
Display <table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td></td><td>2 x LED, yellow</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr></table>
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analog output and pulse output
Clearly readable color display with red/green color change
No inlet and output pipe lengths required
Convenient operation via buttons or parameter setting via IO-Link