SM7100 – фото
Фото
Видео

На SM7100

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output function normally open / closed; (configurable); analog
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; EPDM
Electrical design PNP/NPN
Measuring range 0.01...3
Process connection G 3/4 DN20

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>0.2...50 l/min</td><td>0.01...3 m³/h</td></tr></table>
Process connection threaded connection G 3/4 DN20 flat seal
Application
System gold-plated contacts
Application Totalizer function; for industrial applications
Installation connection to pipe by means of an adapter
Media Conductive liquids; water; water-based media
Note on media <table><tr><td>conductivity: ≥ 20 µS/cm</td></tr><tr><td>viscosity: < 70 mm²/s (40 °C)</td></tr></table>
Medium temperature -10...70
Pressure rating <table><tr><td>16 bar</td><td>1.6 MPa</td></tr></table>
MAWP (for applications according to CRN) <table><tr><td>10.4 bar</td><td>1.04 MPa</td></tr></table>
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption 95; (24 V)
Protection class III
Reverse polarity protection yes
Power-on delay time 5
Measuring principle magnetic-inductive
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputs counter reset
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 200
Number of analog outputs 1
Analog current output 4...20; (scalable)
Max. load 500
Analog voltage output 0...10; (scalable)
Min. load resistance 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>0.2...50 l/min</td><td>0.01...3 m³/h</td></tr></table>
Display range <table><tr><td>-60...60 l/min</td><td>-3.6...3.6 m³/h</td></tr></table>
Resolution <table><tr><td>0.1 l/min</td><td>0.001 m³/h</td></tr></table>
Set point SP <table><tr><td>0.5...50 l/min</td><td>0.027...3 m³/h</td></tr></table>
Reset point rP <table><tr><td>0.2...49.8 l/min</td><td>0.012...2.985 m³/h</td></tr></table>
Analog start point ASP <table><tr><td>0...40 l/min</td><td>0...2.4 m³/h</td></tr></table>
Analog end point AEP <table><tr><td>10...50 l/min</td><td>0.6...3 m³/h</td></tr></table>
In steps of <table><tr><td>0.1 l/min</td><td>0.001 m³/h</td></tr></table>
Volumetric flow quantity monitoring
Pulse value 0.00001...50 000 m³
Pulse length 0,005...2
Temperature monitoring
Dynamic response T05 / T09 T09 = 20 (Q > 5 l/min)
Accuracy / deviations
Flow monitoring
Response time 0.15; (dAP = 0, T19)
Delay time programmable dS, dr 0...50
Damping process value dAP 0...5
Reaction times
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time 5
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>572</td></tr></table>
Operating conditions
Ambient temperature -10...60
Storage temperature -25...80
Protection IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 60947-5-9</td><td></td></tr></table>
CPA approval <table><tr><td>model number</td><td>001MI</td></tr><tr><td>accuracy class</td><td>-</td></tr><tr><td>maximum allowable error</td><td>± 1,5 % FS</td></tr><tr><td>Q (min)</td><td>0,01 m³/h</td></tr><tr><td>Q (t)</td><td>-</td></tr><tr><td>Q (max)</td><td>3
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>20 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 145
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 586.5
Housing tubular
Dimensions Ø 54 / L = 110
Material stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; EPDM
Process connection threaded connection G 3/4 DN20 flat seal
Displays / operating elements
Display <table><tr><td>Display unit</td><td>6 x LED, green (l/min, m³/h, l, m³, 10³, °C)</td></tr><tr><td>Switching status</td><td>2 x LED, yellow</td></tr><tr><td>Measured values</td><td>alphanumeric display, 4-digit</td></tr><tr><td>Programming</td><td>alphanum
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr></table>
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analog output and pulse output
Clearly visible numerical display
Convenient operation via buttons or parameter setting via IO-Link