| Product characteristics |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Process connection |
threaded connection M18 x 1,5 Internal thread |
| Application |
|
| Media |
Liquids; Gases |
| Medium temperature |
-25...80 |
| Pressure rating |
<table><tr><td>300 bar</td><td>30 MPa</td></tr></table> |
| Liquids |
|
| Response time |
1...10 |
| Gases |
|
| Response time |
1...10 |
| Electrical data |
|
| Operating voltage |
19...36 DC |
| Current consumption |
< 60 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
10 |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Outputs |
|
| Total number of outputs |
2 |
| Output signal |
switching signal |
| Electrical design |
NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2.5 |
| Permanent current rating of switching output DC |
250 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
|
| Probe length L |
45 |
| Accuracy / deviations |
|
| Repeatability |
1...5 |
| Note on repeatability |
<table><tr><td>for water 5...100 cm/s; 25 °C</td></tr><tr><td>Factory setting </td></tr></table> |
| Temperature drift |
0.1; (for water 5...100 cm/s; 10...70 °C) |
| Max. temperature gradient of medium |
300 |
| Switch point accuracy |
± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting) |
| Hysteresis |
2...5; (for water 5...100 cm/s; 25 °C; Factory setting) |
| Reaction times |
|
| Response time |
1...10 |
| Software / programming |
|
| Adjustment of the switch point |
pushbuttons |
| Operating conditions |
|
| Ambient temperature |
-25...80 |
| Storage temperature |
-25...100 |
| Protection |
IP 67 |
| Tests / approvals |
|
| EMC |
<table><tr><td>EN 61000-4-2 ESD</td><td>4 kV CD / 8 kV AD</td></tr><tr><td>EN 61000-4-3 HF radiated</td><td>10 V/m</td></tr><tr><td>EN 61000-4-4 Burst</td><td>2 kV</td></tr><tr><td>EN 61000-4-6 HF conducted</td><td>10 V</td></tr></table> |
| Shock resistance |
<table><tr><td>DIN IEC 68-2-27</td><td>50 g (11 ms)</td></tr></table> |
| Vibration resistance |
<table><tr><td>DIN EN 60068-2-6</td><td>20 g (55...2000 Hz)</td></tr></table> |
| MTTF |
244 |
| Mechanical data |
|
| Weight |
249.5 |
| Housing |
tubular |
| Dimensions |
Ø 50 / L = 113 |
| Material |
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
| Process connection |
threaded connection M18 x 1,5 Internal thread |
| Probe diameter |
8.2 |
| Installation length EL |
45 |
| Displays / operating elements |
|
| Display |
<table><tr><td>Function</td><td>10 x LED, three-color</td></tr></table> |
| Remarks |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
|
| Connection |
Connector: 1 x M12; coding: A |