Output function normally open / closed; (configurable)
Materials (wetted parts) stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Probe length L 45
Electrical design PNP
Process connection M18 x 1,5 Internal thread

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Process connection threaded connection M18 x 1,5 Internal thread
Application
Media Liquids; Gases
Medium temperature -25...80
Pressure rating <table><tr><td>300 bar</td><td>30 MPa</td></tr></table>
Liquids
Response time 1...10
Gases
Response time 1...10
Electrical data
Operating voltage 18...36 DC
Current consumption < 60
Protection class III
Reverse polarity protection yes
Power-on delay time 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 250
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Probe length L 45
Accuracy / deviations
Repeatability 1...5
Note on repeatability <table><tr><td>for water 5...100 cm/s; 25 °C</td></tr><tr><td>Factory setting </td></tr></table>
Temperature drift 0.1; (for water 5...100 cm/s; 10...70 °C)
Max. temperature gradient of medium 300
Switch point accuracy ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting)
Hysteresis 2...5; (for water 5...100 cm/s; 25 °C; Factory setting)
Reaction times
Response time 1...10
Software / programming
Adjustment of the switch point pushbuttons
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 3
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>51</td></tr></table>
Operating conditions
Ambient temperature -25...80
Storage temperature -25...100
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 60947-5-9</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN IEC 60068-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>20 g (55...2000 Hz)</td></tr></table>
MTTF 277
Mechanical data
Weight 247.5
Housing tubular
Dimensions Ø 50 / L = 113
Material stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X
Materials (wetted parts) stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connection threaded connection M18 x 1,5 Internal thread
Probe diameter 8.2
Installation length EL 45
Displays / operating elements
Display <table><tr><td>Function</td><td>10 x LED, three-color</td></tr></table>
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Приемущества

Reliable monitoring of liquids and gases in pipes
Variable process connection using adapters
Easy setting of the switch points for quick set-up
Robust stainless steel housing for use in harsh industrial environments
LED bar graph for indication of switch point and flow
Convenient operation via buttons or parameter setting via IO-Link