Характеристики

Pressure rating 40
Output function normally open / closed; (configurable); analog
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Measuring range 10...600
Process connection 3/4" NPT Internal thread

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>10...600 gph</td><td>0.2...10 gpm</td></tr></table>
Process connection threaded connection 3/4" NPT Internal thread
Application
System gold-plated contacts
Application for industrial applications
Media Liquids; water; glycol solutions; Coolants
Note on media <table><tr><td>oil 1 with viscosity: 10 mm²/s (104 °F)</td></tr><tr><td>oil 2 with viscosity: 46 mm²/s (104 °F)</td></tr></table>
Medium temperature 14...212
Pressure rating <table><tr><td>40 bar</td><td>4 MPa</td></tr></table>
MAWP (for applications according to CRN) 40
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 50
Protection class III
Reverse polarity protection yes
Power-on delay time < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable)
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical) 10 million
Number of analog outputs 1
Analog current output 4...20
Max. load 500
Short-circuit protection yes
Overload protection yes
Frequency of the output 0...10000
Measuring/setting range
Measuring range <table><tr><td>10...600 gph</td><td>0.2...10 gpm</td></tr></table>
Display range <table><tr><td>0...720 gph</td><td>0...12 gpm</td></tr></table>
Resolution <table><tr><td>5 gph</td><td>0.1 gpm</td></tr></table>
Set point SP <table><tr><td>5...600 gph</td><td>0.1...10 gpm</td></tr></table>
Reset point rP <table><tr><td>0...595 gph</td><td>0...9.9 gpm</td></tr></table>
Frequency end point, FEP <table><tr><td>40...600 gph</td><td>0.67...10 gpm</td></tr></table>
In steps of <table><tr><td>5 gph</td><td>0.1 gpm</td></tr></table>
Frequency at the end point FRP 10...10000
Measuring dynamics 1:50
Temperature monitoring
Dynamic response T05 / T09 T09 = 120 (Q > 1 l/min)
Accuracy / deviations
Flow monitoring
Response time 0.01
Damping process value dAP 0...5
Damping for the analog output dAA 0...5
Reaction times
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; current output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 3.2
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>567</td></tr></table>
Operating conditions
Ambient temperature 32...140
Note on ambient temperature <table><tr><td>medium temperature < 176 °F </td></tr><tr><td>medium temperature < 212 °F: 32...104 °F</td></tr></table>
Storage temperature 5...176
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>20 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 145
UL approval <table><tr><td>UL approval number</td><td>I005 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 752.9
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection threaded connection 3/4" NPT Internal thread
Displays / operating elements
Display <table><tr><td>Display unit</td><td>3 x LED, green</td></tr><tr><td>Switching status</td><td>2 x LED, yellow</td></tr><tr><td>Measured values</td><td>alphanumeric display, red/green 4-digit</td></tr><tr><td>Programming</td><td>alphanumeric display, 4-digi
Remarks
Remarks <table><tr><td> Use of 200 micron filtration is recommended.</td></tr><tr><td> All data refer to water (68 °F).</td></tr><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr></table>
Notes Please note the changed housing design!
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Precise detection of flow in pipes
Suitable for water, oils and glycol solutions
Precise linearized analog output
Robust housing with very high pressure resistance
Lifespan of more than 10 million pressure cycles
Convenient operation via buttons or parameter setting via IO-Link