Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

SB7243 – фото
SB7243 – фото
SB7243 – фото
Фото
Видео

На SB7243

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Pressure rating 100
Output function analog
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Measuring range 0.06...1.5
Process connection G 1 Internal thread

Все характеристики

Product characteristics
Measuring range <table><tr><td>1...25 l/min</td><td>0.06...1.5 m³/h</td><td>16...396.5 gph</td><td>0.26...6.6 gpm</td></tr></table>
Process connection threaded connection G 1 Internal thread
Application
System gold-plated contacts
Media Liquids; oils (viscosity 320 mm²/s at 40 °C)
Medium temperature -10...100
Pressure rating <table><tr><td>100 bar</td><td>10 MPa</td></tr></table>
Note on pressure rating <table><tr><td>at medium temperature >70°C: 80 bar / 8 MPa</td></tr></table>
MAWP (for applications according to CRN) <table><tr><td>78 bar</td><td>7.8 MPa</td></tr></table>
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV ; cULus - Class 2 source required)
Current consumption < 50
Protection class III
Reverse polarity protection yes
Power-on delay time < 3
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link
Max. voltage drop switching output DC 2
Max. current load per output 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature)
Analog current output 4...20
Max. load 500
Short-circuit protection yes
Overload protection yes
Frequency of the output 0...10000
Measuring/setting range
Measuring range <table><tr><td>1...25 l/min</td><td>0.06...1.5 m³/h</td><td>16...396.5 gph</td><td>0.26...6.6 gpm</td></tr></table>
Display range <table><tr><td>0...30 l/min</td><td>0...1.8 m³/h</td><td>0...475.5 gph</td><td>0...7.93 gpm</td></tr></table>
Resolution <table><tr><td>0.01 l/min</td><td>0.001 m³/h</td><td>0.1 gph</td><td>0.001 gpm</td></tr></table>
Set point SP <table><tr><td>0.16...25 l/min</td><td>0.01...1.5 m³/h</td><td>2.5...396 gph</td><td>0.04...6.6 gpm</td></tr></table>
Reset point rP <table><tr><td>0...24.84 l/min</td><td>0...1.49 m³/h</td><td>0...393.5 gph</td><td>0...6.56 gpm</td></tr></table>
Frequency end point, FEP <table><tr><td>1.66...25 l/min</td><td>0.1...1.5 m³/h</td><td>25.6...396 gph</td><td>0.44...6.6 gpm</td></tr></table>
In steps of 10
Frequency at the end point FRP 10...10000
Measuring dynamics 1:50
Temperature monitoring
Dynamic response T05 / T09 T09 = 120 (Q > 1 l/min)
Accuracy / deviations
Flow monitoring
Response time 0.01
Damping process value dAP 0...5
In steps of 0.1
Damping for the analog output dAA 0...5
Reaction times
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; current/frequency output; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color; calibration factor
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time 3.2
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1044</td></tr></table>
Operating conditions
Ambient temperature 0...60
Note on ambient temperature <table><tr><td>medium temperature < 80 °C </td></tr><tr><td>medium temperature < 100 °C: 0...40 °C</td></tr></table>
Storage temperature -15...80
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>20 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 170
UL approval <table><tr><td>UL approval number</td><td>I006 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice
Mechanical data
Weight 1604
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection threaded connection G 1 Internal thread
Switching cycles mechanical 10 million
Displays / operating elements
Display <table><tr><td>Display unit</td><td>6 x LED, green</td></tr><tr><td>Switching status</td><td>2 x LED, yellow</td></tr><tr><td>Measured values</td><td>alphanumeric display, red/green alternating indication 4-digit</td></tr><tr><td>Programming</td><td>alpha
Remarks
Remarks <table><tr><td> Use of 200 micron filtration is recommended.</td></tr><tr><td>All data refer to oil with the following nominal viscosity: 320 mm²/s, 40 °C</td></tr><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td><
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Fast flow or temperature changes do not affect the measurement
High measurement dynamics reduces type versions
No inlet and output pipe lengths required
Specifically adjusted to oil for optimum measurement results
Convenient operation via buttons or parameter setting via IO-Link