Electrical design Relay

Все характеристики

Application
Application Flow monitoring; Temperature monitoring; Wire break monitoring
Electrical data
Operating voltage tolerance -20...10
Operating voltage 24 DC
Current consumption 90
Protection class III
Reverse polarity protection no
Power-on delay time 10...80; (adjustable (fixed-value resistors terminals 22-23))
Number of channels 1
Outputs
Performance in case of a fault In case of undervoltage all relays are de-energized, the LED "LOW VOLTAGE/WIRE BREAK-RELAY" lights
Electrical design Relay
Contact rating 4 A (250 V AC / 30 V DC)
Switching function flow monitoring relay energized when flow is present and during the power-on delay time
Switching function temperature monitoring relay energized when temperature is exceeded
Switching function wire break monitoring relay de-energized in case of wire-break or short circuit
Short-circuit proof no
Overload protection no
Reaction times
Response time < 3
Software / programming
Adjustment of the switch point potentiometer
Selection liquids / gases wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.
Switch point setting potentiometer
Temperature range 0...80
Repeatability switch point / measured value 4
Operating conditions
Ambient temperature -20...60
Note on ambient temperature <table><tr><td>in case of sufficient free space for convection cooling </td></tr></table>
Protection IP 20
Tests / approvals
MTTF 263
Mechanical data
Weight 237.5
Housing rectangular
Type of mounting Mounting on DIN rail; (TH35 (EN 60715))
Dimensions 100 x 25 x 103.5
Material PBT
Displays / operating elements
Display <table><tr><td>Function</td><td>11 x LED</td></tr><tr><td>Switching status</td><td>LED, red</td></tr><tr><td>Switching status</td><td>LED, red</td></tr></table>
Electrical connection
Connection Combicon connector:
Remarks
Remarks <table><tr><td>Recommendation Check the safe functioning of the unit after a short circuit.</td></tr></table>
Pack quantity 1 pcs.

Приемущества

For the connection of flow sensors
Integrated flow, temperature and wire monitoring
Adjustable switching outputs for monitoring flow and temperature
Clearly visible multi-color LED bargraph display
Signal output via potential-free relay contacts