SD6501 – фото
SD6501 – фото
SD6501 – фото
Фото
Видео

На SD6501

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Protection IP 65, IP 67
Approval CE, cULus, CRN, UKCA, DNV, Korea Registered

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>8...2648 scfh</td><td>0.15...44.15 scfm</td><td>1...327.4 ft/s</td></tr></table>
Process connection threaded connection 1/2" NPT external thread DN15
Application
Application for industrial applications
Media compressed air
Medium temperature 14...140
Min. bursting pressure 928
Pressure rating 232
MAWP (for applications according to CRN) 9.7
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 80
Protection class III
Reverse polarity protection yes
Power-on delay time 1
Inputs / outputs
Total number of inputs and outputs 2; (configurable)
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 150; (per output)
Number of analog outputs 1
Analog current output 4...20; (scalable)
Max. load 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>8...2648 scfh</td><td>0.15...44.15 scfm</td><td>1...327.4 ft/s</td></tr></table>
Display range <table><tr><td>0...3178 scfh</td><td>0...52.95 scfm</td><td>0...393 ft/s</td></tr></table>
Resolution <table><tr><td>2 scfh</td><td>0.05 scfm</td><td>0.2 ft/s</td></tr></table>
Set point SP <table><tr><td>23...2648 scfh</td><td>0.38...44.13 scfm</td><td>2.8...327.3 ft/s</td></tr></table>
Reset point rP <table><tr><td>10...2635 scfh</td><td>0.16...43.91 scfm</td><td>1.2...325.7 ft/s</td></tr></table>
Analog start point ASP <table><tr><td>0...2119 scfh</td><td>0...35.31 scfm</td><td>0...261.9 ft/s</td></tr></table>
Analog end point AEP <table><tr><td>530...2649 scfh</td><td>8.83...44.14 scfm</td><td>65.5...327.4 ft/s</td></tr></table>
Low flow cut-off LFC <table><tr><td>3...28 scfh</td><td>0.05...0.47 scfm</td><td>0.4...3.5 ft/s</td></tr></table>
In steps of <table><tr><td>1 scfh</td><td>0.01 scfm</td><td>0.1 ft/s</td></tr></table>
Pressure monitoring
Response time 0.05
Volumetric flow quantity monitoring
Measuring range <table><tr><td>0...100000000 m³</td><td>0...353146667.2 scf</td></tr></table>
Display range <table><tr><td>0...100000000 m³</td><td>0...353146667.2 scf</td></tr></table>
Set point SP <table><tr><td>0.001...10000000 m³</td><td>0.05...353146667.2 scf</td></tr></table>
Pulse value <table><tr><td>0.001...10000000 m³</td><td>0.05...353146667.2 scf</td></tr></table>
In steps of <table><tr><td>0.0001 m³</td><td>0.005 scf</td></tr></table>
Pulse length 0.002...2
Temperature monitoring
Dynamic response T05 / T09 T09 = 0,5
Accuracy / deviations
Temperature coefficient ± 0,07 % MW
Accuracy (in the measuring range) class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F
Repeatability ± (0,4 % MW + 0,1 % MEW)
Reaction times
Response time 0.1; (dAP = 0)
Damping process value dAP 0...5
Software / programming
Parameter setting options hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles <table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Measurement data, standard resolution</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 8
Process data binary 2
Min. process cycle time 7.2
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>863</td></tr></table>
Operating conditions
Ambient temperature 32...140
Storage temperature -4...185
Max. relative air humidity 90
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 60947-5-9</td><td></td></tr></table>
Vibration resistance <table><tr><td>DIN EN 68000-2-6</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 183
UL approval <table><tr><td>UL approval number</td><td>I012 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for stable gases fluid group 2
Mechanical data
Weight 731
Housing rectangular
Dimensions 300 x 45.4 x 71.2
Material PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection threaded connection 1/2" NPT external thread DN15
Displays / operating elements
Display <table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td></td><td>2 x LED, yellow</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> Measuring, display and setting ranges refer to standard volume flow according to DIN ISO 2533.</td></tr><tr><td> For information about installat
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Приемущества

Precise measurement of flow, consumption, pressure and medium temperature
High accuracy, repeatability and measurement dynamics
For detecting compressed air in industrial use
Red/green display for clear identification of the acceptable range
Display can be rotated for optimum alignment
Convenient operation via buttons or parameter setting via IO-Link