| Resolution |
8192 steps; 65536 revolutions; 29 bit |
| Shaft design |
hollow shaft open to one side |
| Shaft diameter |
12 |
| Function principle |
absolute |
| Revolution type |
multiturn |
| Detection system |
magnetic |
| Application |
Mobile applications; cranes and hoist machines |
| Operating temperature (active) |
-40...85 |
| Operating voltage |
8...36 DC |
| Current consumption |
< 60; ((24 V DC)) |
| Power consumption |
1.5 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Overvoltage protection |
yes; (< 60 V DC) |
| Power-on delay time |
< 2 |
| Contact rating |
max. 1,5 A (24 V DC ) |
| Code |
binary |
| Resolution |
8192 steps; 65536 revolutions; 29 bit |
| Accuracy |
|
| Repeatability |
± 0,1 °; (magnetic) |
| Response time to safety request |
7 |
| Parameter setting options |
scaling; preset; Baud rate; node ID; limit switch; gear function; monitoring window; Counting direction; speed parameters; integration time; ifm mode |
| Number of CAN interfaces |
2 |
| Transmission rate |
20 kBit/s... 1 MBit/s |
| Terminating resistor |
yes; (Extern M12 (z.B. E11590)) |
| Protocol |
CANopen; CANopen Safety; CAN Spezifikation 2.0 A |
| Factory settings |
| Baud rate: 250 kBit/s | | node ID: 32 |
|
| Version |
CiA 406 V4.1.0; CiA 301 V4.2.0; CiA DSP-305 V3.0.0 LSS; EN 50325-4; EN 50325-5; ISO 11898 |
| Ambient temperature |
-40...85 |
| Storage temperature |
-40...90 |
| Note on storage temperature |
|
| Max. relative air humidity |
98 |
| Max. height above sea level |
5000 |
| Protection |
IP 67; IP 69K; (with ifm socket duly screwed on) |
| Chemical media |
| test according to ISO 16750-5 | | | | | the following media were tested at 85 °C for 22 hours | diesel | | biodiesel | | hydraulic fluids | | (Fuchs Hydrotherm 46 M HFC, | | (Fuchs Renoling B15 VG 46 HLP, | | Liqui Moly Hydrauliköl HEES 46) | | brake fluid | | (K2 TURBO DOT 4) | | urea | | (Adblue) | | the following media were tested for 22 hours at 23 °C | preservative | | (Pfinder W550) | | cold cleaner | | (Nigrin cold cleaner) | | ammonia-based cleaner | | (EMSAL Kraft und Grundreiniger) | | alkaline cleaner | | (Kärcher RM 69 FloorPro) | | the following media were tested for 2 hours at 23 °C | windscreen washer fluid | | (Sonax Clear View) | | Fahrzeugreinigungsmittel | | (Förch R527 car shampoo concentrate) | | wheel rim cleaner | | (Sonax Xtreme) | | de-icer | | (Eastman Clearway) | | the following media were tested for 10 minutes at 23 °C | lead-free petrol | | alcohol |
|
| EMC |
| IEC 61000-4-2 ESD 6 | 6 kV CD / 15 kV AD | | IEC 61000-4-3 HF radiated | 20 V/m (27...1000MHz) | | 10 V/m (1000...2000MHz) | | 3 V/m (2000...6000MHz) | | IEC 61000-4-4 Burst | 4 kV | | IEC 61000-4-5 Surge | 2 kV (screen) | | IEC 61000-4-6 HF | 20 V | | IEC 55011 | class B | | IEC 61000-4-8 magnetic fields | 30 A/m (50 Hz) / 1000 A/m (0 Hz) Failure criterion A |
|
| Shock resistance |
| IEC 60068-2-27 | 100 g 6 ms half-sine; 100 shocks each in every direction of the 3 coordinate axes |
|
| Vibration resistance |
| IEC 60068-2-64 | 15 g Sinus / 50...2000 Hz | | ISO 19014-3 | 5.7 g RMS |
|
| Salt spray test |
| IEC 60068-2-52 | severity level 5 |
|
| Standard |
compliant with ECE R 10 Rev. 6 |
| Complies with the requirements |
| ISO 13849-1 Category 3, PL d | | IEC 61508 SIL 2 | | IEC 61800-5-2 | | IEC 61800-5-3 |
|
| MIssion time TM |
175800 |
| Mission time TM (additional indication) |
|
| PFH |
2,00E-8 |
| Weight |
726.95 |
| Housing |
tubular |
| Dimensions |
Ø 58 / L = 64.7 |
| Material |
sealings: NBR/HNBR; Display: UV-stabilized polycarbonate; Connections: diecast zinc nickel-plated (axial)/(radial) |
| Max. revolution, mechanical |
6000 |
| Max. starting torque |
0.05 |
| Reference temperature torque |
20 |
| Shaft design |
hollow shaft open to one side |
| Shaft diameter |
12 |
| Shaft material |
| stainless steel (1.4305 / 303) |
|
| Fixing flange |
direct flange; Ø 63 mm |
| Remarks |
| material for secure mounting not supplied; fixing must be done by the user | | meets the EMC requirements for use in agricultural and forestry machinery, earthworks and construction machines and industrial trucks | | can be used in applications up to Ag PL d in accordance with ISO 25119, up to MPL d in accordance with ISO 19014-3 |
|
| Pack quantity |
1 pcs. |
|
Connector: 1 x M12; coding: A; (open M12 connections must be covered with appropriate protective caps) |
|
Connector: 1 x M12; coding: A; (open M12 connections must be covered with appropriate protective caps) |