Shaft design hollow shaft open to one side
Function principle absolute
Resolution 8192 steps; 65536 revolutions; 29 bit
Dimensions Ø 58 / L = 88.2
Shaft diameter 12

Все характеристики

Resolution 8192 steps; 65536 revolutions; 29 bit
Shaft design hollow shaft open to one side
Shaft diameter 12
Function principle absolute
Revolution type multiturn
Detection system magnetic
Application Mobile applications; cranes and hoist machines
Operating temperature (active) -40...85
Operating voltage 8...36 DC
Current consumption < 60; ((24 V DC))
Power consumption 1.5
Protection class III
Reverse polarity protection yes
Overvoltage protection yes; (< 60 V DC)
Power-on delay time < 2
Contact rating max. 1,5 A (24 V DC )
Code binary
Resolution 8192 steps; 65536 revolutions; 29 bit
Accuracy
non-safety0.2
safety0.5
Repeatability ± 0,1 °; (magnetic)
Response time to safety request 7
Parameter setting options scaling; preset; Baud rate; node ID; limit switch; gear function; monitoring window; Counting direction; speed parameters; integration time; ifm mode
Number of CAN interfaces 2
Transmission rate 20 kBit/s... 1 MBit/s
Terminating resistor yes; (Extern M12 (z.B. E11590))
Protocol CANopen; CANopen Safety; CAN Spezifikation 2.0 A
Factory settings
Baud rate: 250 kBit/s
node ID: 32
Version CiA 406 V4.1.0; CiA 301 V4.2.0; CiA DSP-305 V3.0.0 LSS; EN 50325-4; EN 50325-5; ISO 11898
Ambient temperature -40...85
Storage temperature -40...90
Note on storage temperature
dry
Max. relative air humidity 98
Max. height above sea level 5000
Protection IP 67; IP 69K; (with ifm socket duly screwed on)
Chemical media
test according to ISO 16750-5
the following media were tested at 85 °C for 22 hoursdiesel
biodiesel
hydraulic fluids
(Fuchs Hydrotherm 46 M HFC,
(Fuchs Renoling B15 VG 46 HLP,
Liqui Moly Hydrauliköl HEES 46)
brake fluid
(K2 TURBO DOT 4)
urea
(Adblue)
the following media were tested for 22 hours at 23 °Cpreservative
(Pfinder W550)
cold cleaner
(Nigrin cold cleaner)
ammonia-based cleaner
(EMSAL Kraft und Grundreiniger)
alkaline cleaner
(Kärcher RM 69 FloorPro)
the following media were tested for 2 hours at 23 °Cwindscreen washer fluid
(Sonax Clear View)
Fahrzeugreinigungsmittel
(Förch R527 car shampoo concentrate)
wheel rim cleaner
(Sonax Xtreme)
de-icer
(Eastman Clearway)
the following media were tested for 10 minutes at 23 °Clead-free petrol
alcohol
EMC
IEC 61000-4-2 ESD 66 kV CD / 15 kV AD
IEC 61000-4-3 HF radiated20 V/m (27...1000MHz)
10 V/m (1000...2000MHz)
3 V/m (2000...6000MHz)
IEC 61000-4-4 Burst4 kV
IEC 61000-4-5 Surge2 kV (screen)
IEC 61000-4-6 HF20 V
IEC 55011class B
IEC 61000-4-8 magnetic fields30 A/m (50 Hz) / 1000 A/m (0 Hz) Failure criterion A
Shock resistance
IEC 60068-2-27100 g 6 ms half-sine; 100 shocks each in every direction of the 3 coordinate axes
Vibration resistance
IEC 60068-2-6415 g Sinus / 50...2000 Hz
ISO 19014-35.7 g RMS
Salt spray test
IEC 60068-2-52severity level 5
Standard compliant with ECE R 10 Rev. 6
Complies with the requirements
ISO 13849-1 Category 3, PL d
IEC 61508 SIL 2
IEC 61800-5-2
IEC 61800-5-3
MIssion time TM 175800
Mission time TM (additional indication)
20 years
PFH 2,00E-8
Weight 678.5
Housing tubular
Dimensions Ø 58 / L = 88.2
Material flange, housing: aluminum; sealings: NBR/HNBR; Display: UV-stabilized polycarbonate; Connections: diecast zinc nickel-plated (axial)/(radial)
Max. revolution, mechanical 6000
Max. starting torque 0.05
Reference temperature torque 20
Shaft design hollow shaft open to one side
Shaft diameter 12
Shaft material
stainless steel (1.4305 / 303)
Fixing flange direct flange; Ø 63 mm
Remarks
material for secure mounting not supplied; fixing must be done by the user
meets the EMC requirements for use in agricultural and forestry machinery, earthworks and construction machines and industrial trucks
can be used in applications up to Ag PL d in accordance with ISO 25119, up to MPL d in accordance with ISO 19014-3
Pack quantity 1 pcs.
Connector: 1 x M12; coding: A; (open M12 connections must be covered with appropriate protective caps)
Connector: 1 x M12; coding: A; (open M12 connections must be covered with appropriate protective caps)

Приемущества

Easy integration of the TÜV Rheinland-certified safety subsystem with ifm mode
safety subsystem with CANopen Safety support
Suitable for use in safety functions up to SIL2 / PL d category 3
Certified to the following standards: IEC 61800-5-3, IEC 61508 and ISO 13849-1
Maintenance-free safety encoder with fully magnetic detection