Характеристики

Number of beams 3
Protected area height 810
Protection area width (low light intensity) 0...7
Complies with the requirements ISO 13849-1: 2015 Category 4, PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
Product designation Safety light grid

Все характеристики

Type of light Infrared light
Electrical design PNP
Protection IP 65; IP 67; IP 69K; (with protective tube: IP 69K)
Protective function Access prevention body protection
Operating voltage tolerance 20
Operating voltage 24 DC
Protection class III
Reverse polarity protection yes
Power-on delay time < 2
Type of light Infrared light
Wave length 950
Current consumption 83
Current consumption heating 417
Current consumption 42
Current consumption heating 417
Electrical design PNP
Number of OSSD outputs 2
Max. current load per OSSD output 400; (24 V)
Short-circuit protection yes
Protected area height 810
Number of beams 3
Protection area width (low light intensity) 0...7
Protection area width (high light intensity) 3...15
Response time 2.5
Ambient temperature -20...55
Max. relative air humidity 95
Protection IP 65; IP 67; IP 69K; (with protective tube: IP 69K)
EMC
IEC 61496-1
Shock resistance
IEC 61496-1
Vibration resistance
IEC 61496-1
ESPE type (IEC 61496-1) 4
Complies with the requirements
ISO 13849-1: 2015 Category 4, PL e
IEC 61508 SIL 3
IEC 62061 SIL 3
MIssion time TM 175200
PFH 1,0E-08
Weight 6450
Dimensions 1077 x 76 x 74
Material protective tube: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); sealing: silicone
Length L 1077
Display
transmitter1 x LED
receiver2 x LED
Pack quantity 1 pcs.
Connection Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm²
Connection Cable: 15 m, PVC; 8 x 0.34 mm²

Приемущества

High protection rating for the food and beverage industry
Integrated protective tube for steam and high pressure cleaning resisitance
Reliable protection of hazardous areas
Complies with the requirements of type 4 to IEC 61496
Short and long range selectable via wiring