AL4123 – фото
AL4123 – фото
Фото
Видео

На AL4123

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Communication interface EtherNet/IP
Protection IP 65, IP 66, IP 67, IP 69K
Product designation Ethernet module with EtherNet/IP interface

Все характеристики

Application hygienic systems; I/O modules for field applications
Daisy-chain function voltage supply; fieldbus interface
Operating voltage 20...28 DC; (US ; to PELV)
Current consumption 200...3900; (cULus: 200 ... 3500; US)
Protection class III
Max. current load total 3.6
Overall current rating (UL) 3.2
Number of inputs and outputs Number of digital inputs: 16
Number of digital inputs 16; (type 2 according to IEC 61131-2)
Switching level high 11...30
Switching level low 0...5
Digital inputs protected against short circuits yes
Parameter setting options Counter function
Functions and parameters
FunctionCTU (Up Counter), CTD (Down Counter), CTUD (Up-Down Counter), CTDIR (Direction Counter)
number8 (1 counter for each port)
count frequency4500 Hz
main counter32 Bit (0…4.294.967.295)
batch counter16 Bit (0…65.535)
Communication interface Ethernet
Transmission standard 10Base-T; 100Base-TX
Transmission rate 10 MBit/s; 100 MBit/s
Protocol EtherNet/IP
Factory settings
IP address: 192.168.1.250
subnet mask: 255.255.255.0
gateway IP address: 0.0.0.0
MAC address: see type label
Note on interfaces
DHCP, BOOTP, static
DLR (Device Level Ring)
Supported network topologies: line
ring
Ambient temperature -25...60
Storage temperature -25...85
Max. relative air humidity 90
Protection IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K)
Protection rating (NEMA 250) 6P
Degree of soiling 2
Chemical media
ISO 16750-5HLP, CC, DB, DC, DD, CA
NEMA 250 5.13.1AA
EMC
EN 61000-6-2
EN 61000-6-4
Shock resistance
DIN EN 60068-2-27
Vibration resistance
DIN EN 60068-2-64 2009-04
DIN EN 60068-2-6 2008-10
MTTF 129
Weight 437
Housing rectangular
Type of mounting Backplane mounting
Dimensions 208 x 59.3 x 38.4
Material housing: PA grey; Socket: stainless steel (1.4404 / 316L)
Sealing material EPDM
Items supplied
Protective cap: 1 x M12, stainless steel, E12542
Remarks
Further information is available in the manual.
Pack quantity 1 pcs.
IN / OUT XF1, XF2 Connector: M12; coding: D; sealing: EPDM
Digital Input X1...X8 Connector: M12; coding: A; sealing: EPDM
XD1 Connector: M12; coding: L
XD2 Connector: M12; coding: L; sealing: EPDM

Приемущества

Fieldbus module with digital inputs
Direct connection of sensors to the fieldbus for a clear wiring structure
High-frequency counter function integrated in the Ethernet module
Robust housing for use in the food industry
High protection rating for the food and beverage industry