Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

AC2055 – фото
Фото
Видео

На AC2055

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Number of digital inputs 4
Sensor supply of the inputs AS-i

Все характеристики

Application field installation; for use in wet environments
Operating voltage 26.5...31.6 DC
Max. current consumption from AS-i 170
Integrated watchdog yes
Number of inputs and outputs Number of digital inputs: 4; Number of pneumatic outputs: 2
Number of digital inputs 4; (2 x 2)
Input circuit of digital inputs PNP
Sensor supply of the inputs AS-i
Voltage supply 20...30
Max. total current rating of inputs 100
Input current High > 3
Input current low < 1.5
Switching level high > 10
Digital inputs protected against short circuits yes
Number of pneumatic outputs 2
Actuator supply outputs AS-i
Ambient temperature 0...55
Note on ambient temperature
with special compressed air treatment: < 0 °C
the derating of the current load indicated in the operating instructions is to be taken into account at the following ambient temperature: > 50 °C
Storage temperature -20...80
Max. relative air humidity 90; (non condensing)
Max. height above sea level 2000
Protection IP 67
Degree of soiling 2
EMC
EN 62026-2
EN IEC 61000-6-2
EN IEC 61000-6-4
EN IEC 61326-1
Extended addressing mode no
AS-i master profile M2; M3; M4
AS-i profile S-7.F.F
AS-i I/O configuration 7
AS-i ID code F.F
Data bits
Data bitD0D1D2D3
Inputs / outputsI-1I-2I-3/ O-3I-4 / O-4
Pin4242
Weight 263.5
Housing rectangular
Type of mounting AS-i interface to FC and SC lower parts
Dimensions 107 x 45 x 47
Material housing: PBT; metal parts: stainless steel (1.4305 / 303); sealing: FKM
Pneumatic system 2 x 3/2-way seat valves
Operating pressure range 2...8
Note on working pressure range
incl. possible pressure peaks
Air flow at 6/5 bar 350
Air flow at 6/0 bar 550
Permissible compressed air filtered (5 µm); lubricated (ISO-VG10) or not lubricated
Tube fittings Legris LF 3000/8
Exhaust exhaust can be discharged through tube connection
Display
PowerLED, green (AS-i)
Switching statusLED, yellow (I1...I4, O3...O4)
Module connection Flat cable
Accessories (optional)
Silencer:, E75232
Remarks
Please see the notes on compressed air and EMC/ESD under "Downloads"
Pack quantity 1 pcs.
Connector: M12; coding: A
Connector: M12; coding: A

Приемущества

For the decentralized triggering of cylinders and valve actuators
Combination of AS-i I/O module and solenoid valve
High energy efficiency due to decentralized application near the actuator
Reduced installation and wiring complexity
Easy mounting and wiring on module lower part