| Application |
|
| Application |
field installation; for use in wet environments |
| Electrical data |
|
| Operating voltage |
26.5...31.6 DC |
| Max. current consumption from AS-i |
150 |
| Integrated watchdog |
yes |
| Inputs / outputs |
|
| Number of inputs and outputs |
Number of digital inputs: 2; Number of pneumatic outputs: 2 |
| Inputs |
|
| Number of digital inputs |
2 |
| Input circuit of digital inputs |
PNP |
| Sensor supply of the inputs |
AS-i |
| Voltage supply |
20...30 |
| Max. total current rating of inputs |
100 |
| Input current High |
> 3 |
| Input current low |
< 1.5 |
| Switching level high |
> 10 |
| Digital inputs protected against short circuits |
yes |
| Outputs |
|
| Number of pneumatic outputs |
2 |
| Actuator supply outputs |
AS-i |
| Operating conditions |
|
| Ambient temperature |
0...55 |
| Note on ambient temperature |
<table><tr><td>with special compressed air treatment: < 0 °C</td></tr><tr><td>the derating of the current load indicated in the operating instructions is to be taken into account at the following ambient temperature: > 50 °C</td></tr></table> |
| Storage temperature |
-20...80 |
| Max. relative air humidity |
90; (non condensing) |
| Max. height above sea level |
2000 |
| Protection |
IP 67 |
| Degree of soiling |
2 |
| Tests / approvals |
|
| EMC |
<table><tr><td>EN 62026-2</td><td></td></tr><tr><td>EN IEC 61000-6-2</td><td></td></tr><tr><td>EN IEC 61000-6-4</td><td></td></tr><tr><td>EN IEC 61326-1</td><td></td></tr></table> |
| AS-i classification |
|
| Extended addressing mode |
no |
| AS-i master profile |
M2; M3; M4 |
| AS-i profile |
S-3.F.F |
| AS-i I/O configuration |
3 |
| AS-i ID code |
F.F |
| Data bits |
<table><tr><td>Data bit</td><td>D0</td><td>D1</td><td>D2</td><td>D3</td></tr><tr><td>Inputs / outputs</td><td>I-1</td><td>I-2</td><td>O-3</td><td>O-4</td></tr></table> |
| Mechanical data |
|
| Weight |
254.5 |
| Housing |
rectangular |
| Type of mounting |
AS-i interface to FC and SC lower parts |
| Dimensions |
45 x 80 x 47 |
| Material |
PBT |
| Pneumatic system |
2 x 3/2-way seat valves |
| Operating pressure range |
2...8 |
| Note on working pressure range |
<table><tr><td>incl. possible pressure peaks </td></tr></table> |
| Air flow at 6/5 bar |
350 |
| Air flow at 6/0 bar |
550 |
| Permissible compressed air |
filtered (5 µm); lubricated (ISO-VG10) or not lubricated |
| Tube fittings |
Legris LF 3000/8 |
| Exhaust |
exhaust can be discharged through tube connection |
| Displays / operating elements |
|
| Display |
<table><tr><td>Power</td><td>LED, green (AS-i)</td></tr><tr><td>Switching status</td><td>LED, yellow (I1...I2, O3...O4)</td></tr></table> |
| Electrical connection |
|
| Module connection |
Flat cable |
| Accessories |
|
| Accessories (optional) |
<table><tr><td>Silencer:, E75232</td></tr></table> |
| Remarks |
|
| Remarks |
<table><tr><td> Please see the notes on compressed air and EMC/ESD under "Downloads"</td></tr></table> |
| Pack quantity |
1 pcs. |
| Electrical connection - Socket I-1 |
|
| Electrical connection - Socket I-2 |
|