Характеристики

Protection IP 65, IP 67
Image resolution 3D: 352 x 264
Dimensions 72 x 65 x 82.6
Material housing: diecast aluminium; front lens: gorilla glass; Function display: PA
Angle of aperture 3D: 60 x 45

Все характеристики

Type of light Infrared light
Image resolution 3D 352 x 264
Angle of aperture 3D 60 x 45; (nominal value without lens distortion correction)
Max. reading rate 25
Housing rectangular
Application Camera for the output of 3D image data
Operating voltage tolerance -15...20
Operating voltage 24 DC; (EN 61131-2)
Current consumption 350; (typical)
Max. current consumption 830; (mean value at 24 VDC ; with switched outputs ; <1600 peak current pulsed)
Protection class III
Overvoltage category II
Type of light Infrared light
Image sensor PMD 3D ToF-Chip
Integrated lighting yes; (infrared: 850 nm)
Number of inputs and outputs Number of digital inputs: 1; Number of digital outputs: 2
Trigger 24 V PNP/NPN (IEC 61131-2 Typ 3)
Number of digital inputs 1; (including trigger input)
Input circuit of digital inputs 24 V PNP/NPN; (configurable; IEC 61131-2 Typ 3)
Total number of outputs 2
Electrical design 24 V PNP/NPN; (EN 61131-2)
Number of digital outputs 2; (configurable)
Max. voltage drop switching output DC 1
Max. current load per output 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Operating distance 300...8000
Note on operating distance
object size: 200 x 200 mm
reflectivity: 18 %
Image resolution 3D 352 x 264
Angle of aperture 3D 60 x 45; (nominal value without lens distortion correction)
Max. reading rate 25
Measuring range < 30
Parameter setting options via PC with ifm Vision Assistant or XML-RPC; software API for C, C++ and Halcon
Communication interface Ethernet
Number of Ethernet interfaces 1
Transmission standard 10Base-T; 100Base-TX
Transmission rate 10 MBit/s; 100 MBit/s
Protocol TCP/IP
Factory settings
IP address: 192.168.0.69
subnet mask: 255.255.255.0
gateway IP address: 192.168.0.201
Usage type Parameter setting; Data transmission
Ambient temperature -10...50
Storage temperature -40...85
Max. relative air humidity 90; (non condensing)
Max. height above sea level 4000
Protection IP 65; IP 67
Degree of soiling 3
Max. immunity to extraneous light 8; (with reduced measuring accuracy and repeatability: < 100)
EMC
DIN EN IEC 61000-6-4radiation of interference / industrial environments
DIN EN IEC 61000-6-2noise immunity / industrial environments
Shock resistance
DIN EN 60068-2-2750 g / (11 ms) not repetitive
DIN EN 60068-2-2740 g / (6 ms) repetitive
Vibration resistance
DIN EN 60068-2-62 g / (10...150 Hz)
DIN EN 60068-2-642.3 g RMS / (10...500 Hz)
Laser protection class 1
Notes on laser protection
Caution invisible laser radiation
EN 60825-1:2014 +A11:2021
IEC 60825-1:2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
Electrical safety
DIN EN IEC 61010-2-201electrical supply only via PELV circuits
MTTF 37
Weight 766.95
Housing rectangular
Dimensions 72 x 65 x 82.6
Material housing: diecast aluminium; front lens: gorilla glass; Function display: PA
Tightening torque < 0.8
Display
Function2 x LED, green Ethernet Power
Switching status2 x LED, yellow OUT 1 OUT 2
Items supplied
Protective covers
spring washers
Remarks
Repeatability and accuracy depend on the image settings and the environmental conditions.
The data sheet values apply to typical settings and conditions.
Pack quantity 1 pcs.
Connector: 1 x M12; coding: D
Connector: 1 x M12; coding: A

Приемущества

Visual assessment of distance, level or volume
Reliable distance measurement due to time-of-flight measurement (ToF / Time-of-Flight)
Illumination, measurement and evaluation in one unit
Output of 93,000 distance and grey values per measurement for a detailed evaluation of the application
Integration by means of intuitive parameter setting software