Фото
Видео
Характеристики
| Operating frequency | 13,56 |
| Communication interface | IO-Link |
| Dimensions | 40 x 40 x 54 |
| Product designation | Read/write antenna |
| Radio approval for | USA, Canada, EU/RED, Australia, Japan, China, Taiwan, India, Singapore, Malaysia, Brazil, Mexico, New Zealand, South Korea, Vietnam, Indonesia |
Все характеристики
| Application | Detection of objects on transport equipment | |||||||||
| Radio approval for | USA; Canada; EU/RED; Australia; Japan; China; Taiwan; India; Singapore; Malaysia; Brazil; Mexico; New Zealand; South Korea; Vietnam; Indonesia | |||||||||
| Note on radio approval |
|
|||||||||
| Operating voltage | 19.2...28.8 DC | |||||||||
| Current consumption | < 50 | |||||||||
| Protection class | III | |||||||||
| Operating frequency | 13,56 | |||||||||
| RFID standard | ISO 15693 | |||||||||
| Distance to the ID tag |
|
|||||||||
| Communication interface | IO-Link | |||||||||
| Transmission type | COM2 (38,4 kBaud) | |||||||||
| IO-Link revision | 1.1 | |||||||||
| SDCI standard | IEC 61131-9 | |||||||||
| Profiles |
|
|||||||||
| SIO mode | no | |||||||||
| Required master port class | A | |||||||||
| Min. process cycle time | 22 | |||||||||
| Supported DeviceIDs |
|
|||||||||
| Ambient temperature | -20...60 | |||||||||
| Storage temperature | -25...80 | |||||||||
| Protection | IP 67; IP 69K | |||||||||
| Shock resistance |
|
|||||||||
| Vibration resistance |
|
|||||||||
| MTTF | 567 | |||||||||
| UL approval |
|
|||||||||
| Weight | 175.55 | |||||||||
| Housing | rectangular | |||||||||
| Mounting | flush mountable | |||||||||
| Dimensions | 40 x 40 x 54 | |||||||||
| Material | housing: PA; metal parts: stainless steel | |||||||||
| Display |
|
|||||||||
| Pack quantity | 1 pcs. | |||||||||
| Connection | Connector: 1 x M12; coding: A |
Приемущества
| For the reliable identification of ID tags on workpiece carriers and products |
| Robust housing for applications in mounting, feeding and handling technology |
| High protection rating for the requirements of harsh industrial environments |
| Five selectable positions of the sensing face |
| For connection to IO-Link master version 1.1 by means of industry standard M12 connection |