| Technical Data |
|
| Protocol |
EtherNet/IPModbus® TCP |
| Dimensions (W x L x H) |
40 x 91 x 50 mm |
| Product weight |
98 |
| Ambient temperature |
-550 |
| Storage temperature |
-2070 |
| Degree of protection |
IP65IP67 |
| Corrosion resistance class CRC |
2 - Moderate corrosion stress |
| LABS (PWIS) conformity |
VDMA24364 zone III |
| CE mark (see declaration of conformity) |
To EU EMC DirectiveIn accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
| Approval |
RCM trademarkc UL us listed (OL) |
| Explosion protection |
Class I, Div. 2 (CA)Class I, Div. 2 (US)Class II, Div. 2 (CA)Class II, Div. 2 (US)Zone 0 (BR)Zone 2 (ATEX)Zone 2 (CA)Zone 2 (CN)Zone 2 (IEC-EX)Zone 2 (KR)Zone 2 (UKEX)Zone 2 (US)Zone 22 (ATEX)Zone 22 (BR)Zone 22 (CA)Zone 22 (CN)Zone 22 (IEC-EX)Zone 22 (KR |
| ATEX category gas |
II 3G |
| ATEX category dust |
II 3D |
| Explosion protection certification outside the EU |
Class I, Div. 2 (CA)Class I, Div. 2 (US)Class II, Division 2 (CA)Class II, Div. 2 (US)Class III (CA)Class III (US)EPL Dc (BR)EPL Dc (CA)EPL Dc (CN)EPL Dc (GB)EPL Dc (IECEx)EPL Dc (KR)EPL Dc (US)EPL Ga (BR)EPL Gc (CA)EPL Gc (CN)EPL Gc (GB)EPL Gc (IECEx)EPL |
| Explosion ignition protection type for gas |
Ex ec IIC Gc X |
| Explosion ignition protection type for dust |
Ex tc IIIC T135°C Dc X |
| Certificate issuing authority |
DNV 23.0350 X/00IBExU16ATEXB021 XIECEx IBE 19.0018 XKTL 24-KA4BO-0392XKTL 24-KA4BO-0393XKTL 24-KA4BO-0394XKTL 24-KA4BO-0395XNEPSI GYJ19.1188XSITIIAS CCC 202032230700686UL E239998 |
| Note on materials |
RoHS-compliant |
| Material housing |
PA |
| LED display, product-specific |
PS: Operating voltage for electronics and load supplyX1: System status of module at I-Port 1X2: System status of module at I-Port 2 |
| LED display, bus-specific |
NS: Network statusTP1: Network active port 1TP2: Network active port 2 |
| Diagnosis |
Communication faultSystem diagnosticsUndervoltage |
| Operator controls |
DIL switch |
| Field bus interface |
2x socket, M12x1, 4-pin, D-coded |
| Max. address volume, inputs |
64 |
| Max. address volume, outputs |
64 |
| Parameterisation |
Diagnostic behaviourFail-safe and idle response |
| Baud rate |
10/100 Mbit/s |
| Internal cycle time |
1 ms per 1 byte of user data |
| Configuration support |
EDS file |
| Additional functions |
AddressConflictDetection (ACD)Acyclic data access via "Explicit Message"EtherNet/IP QuickconnectIP addressing via DHCP, DIL switch, fieldbus or FFTIntegrated switchRing topology (DLR)SNMPStart-up parameterisation in plain text via fieldbusSystem status ca |
| Operational voltage range DC |
1830 |
| Nominal operating voltage DC |
24 |
| Max. power supply |
4 |
| Intern power consumption nominal operating voltage |
Typ. 65 mA |