| Technical Data |
|
| Electrical control |
I-PortIO-Link®Multi-pin plug |
| Electrical I/O system |
no |
| Terminal type |
35 |
| Grid dimension |
26.8 |
| Operating medium |
Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium |
Lubricated operation possible (in which case lubricated operation will always be required) |
| Media temperature |
-550 |
| Ambient temperature |
-560 |
| Storage temperature |
-2040 |
| Degree of protection |
IP65IP67IP69K |
| Corrosion resistance class CRC |
4 - Very high corrosion stress |
| Vibration resistance |
Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance |
Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Operating pressure |
-0.98 |
| Pilot pressure |
38 |
| Operating pressure for valve terminal with internal pilot air supply |
43.5116 |
| LABS (PWIS) conformity |
VDMA24364-B2-L |
| CE mark (see declaration of conformity) |
To EU EMC DirectiveIn accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
| KC mark |
KC-EMV |
| Approval |
RCM trademarkUL - Recognized (OL) |
| Suitable for use with food |
See supplementary material information |
| Note on materials |
RoHS-compliant |
| Material seals |
EPDM |
| Valve terminal structure |
Modular and expandable |
| Max. number of valve positions |
32 |
| Max. number of pressure zones |
32 |
| Type of actuation |
Electric |
| Valve function |
2/2-way, closed, monostable2x3/2-way, monostable, closed2x3/2-way, open, monostable2x3/2-way, open/closed, monostable3/2-way, closed, monostable3/2 open, monostable5/2 bistable5/2-way, monostable5/3-way, pressurised5/3 exhausted5/3 closed |
| Design |
Piston gate valve |
| Type of piloting |
Electric |
| Valve size |
14 |
| Pilot air supply |
ExternalInternal |
| Max. standard nominal flow rate |
780 l/min at 14 mm |
| Suitability for vacuum |
yes |
| Pneumatic connection, port 1 |
G1/4G3/8 |
| Pneumatic connection, port 2 |
G1/4 |
| Pneumatic connection, port 3 |
G1/4G3/8 |
| Pneumatic connection, port 4 |
G1/4 |
| Pilot air port 12/14 |
G1/8 |
| Pilot exhaust port 82/84 |
G1/8 |
| Signal status display |
LED |
| Nominal operating voltage DC |
24 |
| Permissible voltage fluctuations |
+/- 25% |
| Nominal pick-up current per solenoid coil |
50 mA up to 20 ms |
| Nominal current with current reduction |
10 mA after 20 ms |